MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1063/5.0334573

Медицинская библиотека · The Review of scientific instruments · 2026

Electrode erosion and lifetime of field-distortion spark gap switches under 88-kA repetitive discharges.

Wang Xue, Zhou Yiheng, Liang Fengfan, Du Peng, Yuan Wuhan, Thio Y C Francis

СтатьяПеревод пока не подготовлен

Аннотация

This paper systematically investigates the electrode erosion and lifetime characteristics of a three-electrode field-distortion spark gap switch operating at a charging voltage of 4 kV and a peak current of ∼88 kA. Lifetime testing was combined with electrode mass measurements and staged macro- and microscopic characterization to identify the principal degradation processes. The switch exhibits a reproducible non-monotonic delay evolution that correlates with the formation, displacement, and blunting of a cathode surface protrusion. The electrodes exhibit an overall net mass loss, while small early-stage fluctuations may result from material redistribution among the electrodes. Scanning electron microscope observations indicate that repetitive localized thermal shock is the fundamental driving force for crack initiation. Spatially nonuniform energy deposition, governed by arc-root attachment and plasma/gas dynamics, produces distinct pit morphologies and thermal-stress distributions. Type II pits tend to aggregate at crack sites and play an increasingly important role in subsequent discharges. The more severe fragmentation on the anode-facing side of the trigger electrode is attributed to greater inferred plasma exposure and energy deposition, which promote type II pit formation, intergranular crack-network development, and eventual fragment detachment. These results provide insight into electrode material selection and lifetime optimization for high-current spark gap switches.

Для цитирования: Wang Xue, Zhou Yiheng, Liang Fengfan, Du Peng, Yuan Wuhan, Thio Y C Francis. Electrode erosion and lifetime of field-distortion spark gap switches under 88-kA repetitive discharges.. The Review of scientific instruments. 2026. DOI: 10.1063/5.0334573.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.