m+Medelevator.RU
← Поиск публикаций
Analytical chemistry · 2026

Rapid Species-Level Classification of Urinary Pathogens from Raw LC-MS/MS Signals Using Machine Learning.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Pelletier Simon J, Lacombe-Rastoll Antoine, Roux-Dalvai Florence, Leclercq Mickaël, Gotti Clarisse, Bérubé Eve, Bories Pascaline, Thibeault Marie-Ève, Bekker-Jensen Dorte B, Bache Nicolai, Bromirski Maciej, Isabel Sandra, Precioso Frederic, Droit Arnaud

Аннотация

Urinary tract infections are among the most common infections in humans, yet their diagnosis still depends on time-consuming workflows based on microbial culture, followed by MALDI-TOF mass spectrometry. Although LC-MS/MS offers the sensitivity and specificity needed to bypass culture, conventional pipelines depend on lengthy analyses and peptide/protein identification steps, limiting the throughput and hindering its adoption in clinical settings. Here, we introduce a direct, identification-free LC-MS/MS workflow that analyzes raw ion signal and produces species-level microbial identification in about 5 min after preparation, fast enough to meet clinical throughput requirements. Our machine learning-enabled raw-signal pipeline bypasses peptide identification entirely, preserving information and eliminating the traditional interpretation stack. Across 15 independent analytical batches covering 28 clinically relevant pathogens, the method achieved high-confidence classification (MCC = 0.86). Applied to 206 clinical urine specimens across three batches, the approach reached 91% accuracy at clinically actionable microbial loads (greater than 105 CFU/mL) and, critically, 0 false positives in control specimens. The performance was lower for specimens below this threshold. These results show that raw LC-MS/MS spectra contain sufficient biological information for direct microbial diagnosis, establishing an analytical framework for clinical mass spectrometry. This proof-of-concept demonstrates that rapid, culture-free, fast microbial identification is achievable and positions raw signal inference as a promising direction for next-generation diagnostic mass spectrometry.

Предметные рубрики MeSH