Patch Testing for Implanted Medical Device-Related Delayed Hypersensitivity Reactions: Retrospective Analysis of North American Contact Dermatitis Group Data, 2016-2022.

Atwater Amber Reck, Liu Beiyu, Green Cynthia L, Warshaw Erin M, Reeder Margo J, Adler Brandon L, Pratt Melanie D, Fowler Joseph F, Taylor James S, Houle Marie-Claude, Silverberg Jonathan I, Wu Peggy A, Belsito Donald V, Dunnick Cory A, Zippin Jonathan, Mowad Christen, Maibach Howard I, Botto Nina, Yu JiaDe, DeKoven Joel G

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Medical implants are often suspected of causing allergic reactions.

OBJECTIVE

To determine results for 2016-2022 North American Contact Dermatitis Group implant patch testing.

METHODS

Retrospective, cross-sectional analysis of clinical findings and patch test results.

RESULTS

Of 128 Pre-implant cases, 57.8% had ≥1 positive patch test reaction (PPTR). Top implant sites were knee and hip (62.7%). Top PPTRs were nickel 5% (43.0%), nickel 2.5% (29.1%), vanadium (14.3%), and cobalt (11%). Of 170 Post-implant cases, 45.3% had no dermatitis, 29.8% had dermatitis at the implant site, and 14.9% had scattered/generalized distribution. Top implant sites were knee and hip (66.8%). There was ≥1 PPTR in 35.9% of patients. 27/43 (62.8%) allergens ever tested positive, and of these, 77.8% (21/27) had current relevance. Top PPTR were nickel 5% (16.5%), nickel 2.5% (12.9%), cobalt (6.5%), and neomycin (5.9%). Of 170 cases, 18 (10.6%) were diagnosed with allergic contact dermatitis at implant site due to implant, with top allergens titanium oxalate (n = 4), tobramycin (n = 3), cobalt (n = 3), and nickel 5% (n = 3).

CONCLUSIONS

Over half of Pre-implant and just over 1/3 of Post-implant patients had ≥1 PPTR. About 10% of Post-implant patients were diagnosed with allergic contact dermatitis at implant site due to implant. Outcomes data are needed to confirm relevance.

Для цитирования: Atwater Amber Reck, Liu Beiyu, Green Cynthia L, Warshaw Erin M, Reeder Margo J, Adler Brandon L, Pratt Melanie D, Fowler Joseph F, Taylor James S, Houle Marie-Claude, Silverberg Jonathan I, Wu Peggy A, Belsito Donald V, Dunnick Cory A, Zippin Jonathan, Mowad Christen, Maibach Howard I, Botto Nina, Yu JiaDe, DeKoven Joel G. Patch Testing for Implanted Medical Device-Related Delayed Hypersensitivity Reactions: Retrospective Analysis of North American Contact Dermatitis Group Data, 2016-2022.. Dermatitis : contact, atopic, occupational, drug. 2026. DOI: 10.1177/17103568261499055.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.