MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/msc.70285

Медицинская библиотека · Musculoskeletal care · 2026

Measurement Properties of Hand-Held Dynamometry for Ankle Strength Assessment: A COSMIN-Based Systematic Review and Meta-Analysis.

Lourenço Ferreira Matheus Hissa, Völker Oliveira João Victor, Junior Nelson Carvas, Dutra de Oliveira Túlio Medina, Santos Araujo Guilherme Augusto, Filho José Elias, Sabino George Schayer, Malaguti Carla, Felício Diogo Carvalho

СтатьяСистематический обзорМетаанализОбзорПеревод пока не подготовлен

Аннотация

OBJECTIVE

This systematic review and meta-analysis evaluated the measurement properties of handheld dynamometry (HHD) for assessing isometric ankle muscle strength in healthy individuals.

METHODS

A comprehensive search was conducted in PubMed, EMBASE, CINAHL, Web of Science, SPORTDiscus, PsycINFO, Scopus, and the Virtual Health Library, with no language or date restrictions. Observational and methodological studies assessing dorsiflexors, plantar flexors, invertors, or evertors using HHD were eligible if they reported reliability, measurement error, or construct validity against isokinetic dynamometry. Random-effects meta-analyses were performed by measurement property and testing configuration, following COSMIN guidance.

RESULTS

Twenty-four studies were included. Inter-rater reliability was good for dorsiflexors (ICC = 0.89, 95% CI 0.80-0.94), plantar flexors (ICC = 0.86, 95% CI 0.72-0.93), invertors (ICC = 0.79, 95% CI 0.66-0.87), and evertors (ICC = 0.75, 95% CI 0.46-0.90). Intra-rater reliability ranged from good to excellent (ICC = 0.88-0.91). External fixation was associated with numerically higher inter-rater ICCs for dorsiflexors and plantar flexors although subgroup differences were not statistically significant. Construct validity was strong for dorsiflexors (r = 0.87, 95% CI 0.42-0.98) but uncertain for plantar flexors (r = 0.72, 95% CI -0.20-0.96). Measurement error remained indeterminate due to the absence of an established minimal important change. Certainty of evidence was high for reliability and low for construct validity; measurement error was not graded.

CONCLUSION

HHD provides reliable assessment of isometric ankle strength, including without external fixation. Evidence for construct validity, particularly for plantar flexors, and for measurement error remains limited.

Для цитирования: Lourenço Ferreira Matheus Hissa, Völker Oliveira João Victor, Junior Nelson Carvas, Dutra de Oliveira Túlio Medina, Santos Araujo Guilherme Augusto, Filho José Elias, Sabino George Schayer, Malaguti Carla, Felício Diogo Carvalho. Measurement Properties of Hand-Held Dynamometry for Ankle Strength Assessment: A COSMIN-Based Systematic Review and Meta-Analysis.. Musculoskeletal care. 2026. DOI: 10.1002/msc.70285.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.