MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00464-026-13496-9

Медицинская библиотека · Surgical endoscopy · 2026

Automated triage of non-informative frames in minimally invasive surgical videos: a comparative study of domain-specific vision transformers versus general-purpose multimodal models.

Li Peilin, Li Juanjuan, Han Kaihong, Xie Shaonan, Gao Maogang, Liu Qingyi

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Minimally invasive surgery (MIS) videos support education and quality review, but raw recordings contain non-informative frames that impede review and increase storage.

METHODS

We retrospectively analyzed 300,832 frames from 120 MIS videos performed by 30 surgeons. An EndoViT-initialized Vision Transformer (ViT) was evaluated using leave-six-surgeons-out cross-validation and compared with conventional vision models. GPT-4o-mini, LLaVA, and Doubao were separately evaluated under zero- and few-shot prompting on a balanced 400-frame subset that was not sample-size matched to the ViT evaluation. We also explored the association between surgeon experience and non-informative-frame ratio.

RESULTS

In the within-dataset comparison of trained vision models, the EndoViT-initialized ViT achieved an aggregate accuracy and F1-score of 0.942. In an exploratory few-shot analysis within a separate 400-frame balanced benchmark, GPT-4o-mini achieved an accuracy of 0.890 and F1-score of 0.880; exemplar-test disjointness could not be confirmed. Because the ViT and LMM evaluations used different test sets and sample sizes, these estimates do not support a direct comparison of model superiority. The surgeon-level analysis showed no statistically significant association between experience and the non-informative-frame ratio (r = - 0.421, 95% CI - 0.83 to 0.28; p = 0.226).

CONCLUSION

The EndoViT-initialized ViT performed well in this single-institution dataset, whereas prompt-only LMM performance varied in a separate small benchmark. Matched evaluation with documented exemplar-test separation and external validation is required before determining relative performance or clinical readiness. Automated frame triage may support MIS video management with human oversight.

Для цитирования: Li Peilin, Li Juanjuan, Han Kaihong, Xie Shaonan, Gao Maogang, Liu Qingyi. Automated triage of non-informative frames in minimally invasive surgical videos: a comparative study of domain-specific vision transformers versus general-purpose multimodal models.. Surgical endoscopy. 2026. DOI: 10.1007/s00464-026-13496-9.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.