[Value of low-dose multi-slice spiral CT chest scan in diagnosis of coal workers' pneumoconiosis].

Du P, Cao A H, Guo Z W, Shao Q, Xu K

СтатьяПеревод в очереди

Аннотация

Objective

To investigate the value of low-dose multi-slice CT (MSCT) chest scan in the diagnosis of coal workers' pneumoconiosis.

Methods

A total of 90 patients with a confirmed diagnosis of coal workers' pneumoconiosis were enrolled, and under the conditions of fixed tube voltage, pitch, and slice thickness, they underwent CT scan with a normal dose (150 mA) and a low dose (30-50 mA). The quality of images obtained from two scans was compared, and the imaging findings, opacity profusion, stage, and radiation doses were also compared.

Results

Compared with the normal-dose scan, low-dose scan increased the image noise, and the images obtained from scans with doses of 30, 40, and 50 mA did not show significant reductions in signal-to-noise ratio or contrast-to-noise ratio (P>0.05). There was no significant difference in the percentage of image quality between low-dose and normal-dose scans (P>0.05). There were no significant differences in the percentage of various imaging findings, opacity profusion, or percentage of different stages between low-dose (30, 40, and 50 mA) and normal-dose (150 mA) scans (P>0.05).

Conclusion

There are no significant differences between low-dose MSCT chest scan and normal-dose CT in image quality, imaging findings of coal workers' pneumoconiosis, opacity profusion, and stage. Meanwhile, low-dose MSCT chest scan greatly reduces the radiation dose and can be used to assist the diagnosis and follow-up reexamination of coal workers' pneumoconiosis and cover the shortage of high-kilovoltage chest X-ray.

Для цитирования: Du P, Cao A H, Guo Z W, Shao Q, Xu K. [Value of low-dose multi-slice spiral CT chest scan in diagnosis of coal workers' pneumoconiosis].. Zhonghua lao dong wei sheng zhi ye bing za zhi = Zhonghua laodong weisheng zhiyebing zazhi = Chinese journal of industrial hygiene and occupational diseases. 2016. DOI: 10.3760/cma.j.issn.1001-9391.2016.09.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.