MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/jnis-2026-025736

Медицинская библиотека · Journal of neurointerventional surgery · 2026

First multicenter experience with the SOFIA 88 super-large-bore aspiration catheter in mechanical thrombectomy.

Hohenstatt Sophia, Radu Răzvan Alexandru, Negrila Anca, Crossley Robert, Hellstern Victoria, Bhogal Pervinder, Makalanda Levansr, Tomasello Alejandro, Rodrigo Marc, Clarençon Frédéric, Burel Julien, Voss Yves L, Vollherbst Dominik F, Bendszus Martin, Nordmeyer Hannes, Möhlenbruch Markus A

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Super-large-bore aspiration catheters are designed to improve clot engagement and aspiration efficiency during mechanical thrombectomy. However, multiple 0.088-inch platforms are now available, and device-specific clinical performance cannot be inferred from catheter size alone. We report the first multicenter real-world experience with SOFIA 88.

METHODS

This retrospective multicenter European registry included consecutive patients treated with SOFIA 88 for anterior circulation large vessel occlusion involving the internal carotid artery or M1. The primary outcome was successful catheter advancement to the thrombus-vessel interface. Angiographic outcomes included first-pass effect (extended Thrombolysis in Cerebral Infarction (eTICI)≥2c after one pass), final complete reperfusion (eTICI 2c-3), and final successful reperfusion (eTICI≥2b). Safety outcomes included procedural complications, embolization to new territory, intracranial hemorrhage, and symptomatic intracranial hemorrhage.

RESULTS

Eighty-one patients from eight centers were included. SOFIA 88 reached the thrombus-vessel interface in 67/81 cases (82.7%), most often using smaller-catheter support (57/81, 70.4%). SOFIA 88 standalone first-pass effect occurred in 32/81 patients (39.5%) using the full real-world cohort denominator and in 32/67 patients (47.8%) among cases with successful SOFIA 88 target access. Final complete and successful reperfusion was achieved in 67/81 (82.7%) and 79/81 (97.5%) patients, respectively. Procedural adverse events occurred in 3/81 (3.7%), embolization to new territory in 1/81 (1.2%), and symptomatic intracranial hemorrhage in 5/81 (6.2%). No device-related adverse events occurred.

CONCLUSIONS

SOFIA 88 showed feasible target access, high final reperfusion, favorable standalone first-pass performance after successful target access, and acceptable early safety. Further prospective studies are warranted to define optimal patient selection, delivery strategies, and the role of SOFIA 88 in contemporary thrombectomy practice.

Для цитирования: Hohenstatt Sophia, Radu Răzvan Alexandru, Negrila Anca, Crossley Robert, Hellstern Victoria, Bhogal Pervinder, Makalanda Levansr, Tomasello Alejandro, Rodrigo Marc, Clarençon Frédéric, Burel Julien, Voss Yves L, Vollherbst Dominik F, Bendszus Martin, Nordmeyer Hannes, Möhlenbruch Markus A. First multicenter experience with the SOFIA 88 super-large-bore aspiration catheter in mechanical thrombectomy.. Journal of neurointerventional surgery. 2026. DOI: 10.1136/jnis-2026-025736.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.