MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2025.04.035

Медицинская библиотека · JACC. Cardiovascular interventions · 2025

Procedural Impact of Advanced Calcific Plaque Modification Devices Within Percutaneous Revascularization of Chronic Total Occlusions.

Vadalà Giuseppe, Mashayekhi Kambis, Behnes Michael, Ayoub Mohamed, Gorgulu Sevket, Werner Gerald S, Kalay Nihat, Avran Alexander, Goktekin Omer, Garbo Roberto, Jaroslaw Wojcik, Zaczkiewicz Myron, Arnez Juergen, Pyxaras Stylianos, Christiansen Evald Høj, Gutiérrez-Chico Juan Luis, Maniscalco Laura, Madaudo Cristina, Boudou Nicolaus, Stojkovic Sinisa, Gasparini Gabriele L, Agostoni Pierfrancesco, Diletti Roberto, di Mario Carlo, Bulum Josko, Galassi Alfredo R, EURO CTO Investigators

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеСравнительное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Significant calcifications within a coronary chronic total occlusion (CTO) increase procedural complexity and the risk for complications. Expert consensus documents recommend the use of advanced calcific plaque modification devices (ACPMDs) for calcified CTO percutaneous coronary intervention (PCI), whereas data on their procedural impact are limited.

OBJECTIVES

The aim of this study was to describe trends, settings, and outcomes of PCI of severely calcified CTO performed with and without ACPMDs.

METHODS

Data from 15,329 CTO PCIs enrolled in the ERCTO (European Registry of Chronic Total Occlusion) between 2021 and 2023 were analyzed. On the basis of the presence of severe calcifications within the CTO, the study population was divided into 2 groups: nonsevere (n = 12,289) and severe (n = 3,040) calcium. Then, the severe group was divided into non-ACPMD (n = 2,253) and ACPMD (n = 787), according to the use of ACPMDs.

RESULTS

Compared with the non-ACPMD group, the ACPMD group had higher rates of antegrade wiring (77.9% vs 49.2%; P < 0.001) and technical success (97.6% vs 79.1%; P = 0.001) and lower rates of periprocedural and in-hospital major adverse cardiac and cerebrovascular events (MACCE) (1.8% vs 3.5%; P = 0.001). A severe amount of calcium was independently associated with technical failure (OR: 3.13; 95% CI: 2.43-4.09; P < 0.001) but not with MACCE (OR: 0.88; 95% CI: 0.58-1.35; P = 0.15). Furthermore, extraplaque crossing was independently associated with MACCE (antegrade dissection and re-entry without retrograde contribution: OR: 3.12; 95% CI: 1.79-4.20; P < 0.001; antegrade dissection and re-entry with retrograde contribution: OR: 3.12; 95% CI: 1.67-4.11; P = 0.049; retrograde dissection and re-entry: OR: 1.90; 95% CI: 1.25-2.86; P = 0.002).

CONCLUSIONS

Applying ACPMDs in severely calcified CTO to PCI was associated with higher technical success and lower MACCE rates. The presence of severe coronary calcification on coronary angiography was a marker of clinical and procedural complexity and was associated with technical failure but not with MACCE.

Для цитирования: Vadalà Giuseppe, Mashayekhi Kambis, Behnes Michael, Ayoub Mohamed, Gorgulu Sevket, Werner Gerald S, Kalay Nihat, Avran Alexander, Goktekin Omer, Garbo Roberto, Jaroslaw Wojcik, Zaczkiewicz Myron, Arnez Juergen, Pyxaras Stylianos, Christiansen Evald Høj, Gutiérrez-Chico Juan Luis, Maniscalco Laura, Madaudo Cristina, Boudou Nicolaus, Stojkovic Sinisa, Gasparini Gabriele L, Agostoni Pierfrancesco, Diletti Roberto, di Mario Carlo, Bulum Josko, Galassi Alfredo R, EURO CTO Investigators. Procedural Impact of Advanced Calcific Plaque Modification Devices Within Percutaneous Revascularization of Chronic Total Occlusions.. JACC. Cardiovascular interventions. 2025. DOI: 10.1016/j.jcin.2025.04.035.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.