MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/14992027.2018.1560509

Медицинская библиотека · International journal of audiology · 2019

Distorted sound perception and subjective benefit after stapedotomy - a prospective single-centre study.

Bächinger David, Röösli Christof, Kesterke Rahel, Dalbert Adrian, Péus Dominik, Veraguth Dorothe, Pfiffner Flurin, Huber Alexander

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the quality of perceived sound after stapedotomy over a 1-year follow-up period focussing on incidence of dysacusis, particularly distorted sound perception (DSP). DSP was assessed by (i) determination of the frequencies and hearing level that such perceptions are elicited by pure tones (pure-tone-evoked distorted sound perception, PTE-DSP), a novel psychoacoustic measurement introduced in this paper, and (ii) assessment of patient-reported occurrence of DSP using the Amsterdam Post Operative Sound Evaluation (APOSE) questionnaire (APOSE-DSP).

DESIGN

Prospective study.

STUDY SAMPLE: Patients (n = 23) with otosclerosis undergoing stapedotomy.

RESULTS

An air-bone gap of <20 dB was achieved in 100% of the patients. Three weeks postoperatively, 48% of the patients reported measured PTE-DSP and 39% of the patients experienced APOSE-DSP. The PTE-DSP significantly decreased during the 1-year follow-up period (p = 0.03). Postoperatively, APOSE-DSP was associated with a smaller benefit (improvement in air conduction; p = 0.03), yet, a lower bone conduction pure-tone average was associated with PTE-DSP (p = 0.006).

CONCLUSIONS

DSP after stapedotomy is associated with a smaller benefit 3 months after stapedotomy. DSP commonly occur after stapedotomy, but decrease over time. This is important information to be included in patient counselling before stapedotomy.

Для цитирования: Bächinger David, Röösli Christof, Kesterke Rahel, Dalbert Adrian, Péus Dominik, Veraguth Dorothe, Pfiffner Flurin, Huber Alexander. Distorted sound perception and subjective benefit after stapedotomy - a prospective single-centre study.. International journal of audiology. 2019. DOI: 10.1080/14992027.2018.1560509.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.