m+Medelevator.RU
← Поиск публикаций
Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2018

Outcomes of Stapedotomy With Heat-Crimped Prostheses.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Murfee John, O'Connell Brendan, Haynes David, Rivas Alejandro, Dedmon Matthew, Bennett Marc

Аннотация

BACKGROUND: Theoretical disadvantages are associated with the use of heat-crimped piston prostheses in stapedotomy. Loose crimping could result in prosthesis displacement or slippage. Alternatively, overly tight crimping may cause trauma to the incus with resultant necrosis.

OBJECTIVES: 1) Analyze outcomes of patients undergoing stapedotomy with heat-activated piston-style prostheses, and 2) compare outcomes between prostheses made by different manufacturers.

STUDY DESIGN: Retrospective.

SETTING: Vanderbilt Medical Center.

PATIENTS AND METHODS: Cases undergoing stapedotomy between 2005 and 2016 were reviewed. Audiometric assessments were recorded in accordance with American Academy of Otolaryngology-Head and Neck Surgery (AAO-HNS) guidelines. Patients who lacked audiometric follow-up before 6 months or after 1 year were excluded.

INTERVENTION(S): Diagnostic, therapeutic, and rehabilitative.

MAIN OUTCOME MEASURE(S): Postoperative air-bone gap (ABG) and achievement of an ABG is less than or equal to 10 dB.

RESULTS: Three hundred fifty-eight patients met inclusion criteria. At short-term follow-up (<6 mo), the mean ABG was 11 ± 8 dB in the entire cohort; this did not differ based on manufacturer (p = 0.13). The majority of patients (63%) achieved an ABG less than or equal to 10 dB. At longer-term follow-up, the mean ABG was 9 ± 7 dB; again no differences were noted when comparing prosthesis manufacturer (p = 0.20). 70% of patients achieved an ABG less than or equal to 10 dB at longer-term follow-up. When comparing short- to long-term follow-up, ABG did not significantly change over time (p = 0.76). The overall revision rate was 1.9% (n = 7).

CONCLUSION: Favorable hearing outcomes are obtained both short- and long-term following stapedotomy and placement of heat-crimped piston prostheses. Both prosthesis groups appear stable in the middle ear environment long-term, as evidenced by a 1.9% revision rate among them.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты