MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3969/j.issn.1000-4432.2011.02.021

Медицинская библиотека · Eye science · 2011

Sulcus Transscleral Intraocular Lens Suture Fixation through Small Scleral Tunnel Incision.

Wu Wenjie, Li Qing, Yan Duan, Zhang Jianhui, Chen Yi, Zhang Huiying

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the clinical efficiency and safety of sulcus transscleral intraocular lens suture fixation with small incision through scleral tunnel in eyes the with posterior capsule defect or insufficient zonula support.

METHODS

Thirty nine eyes with severe posterior capsule defect and zonula damages caused by small-incision cataract surgery, and those with capsule absence or intraocular lens dislocation were selected in this investigation from February 2007 to December 2009. Sulcus transscleral intraocular lens suture combined with puncture needle-guided external approachab and "one- or two-point fixation" method in the small sclera tunnel incision were employed.

RESULTS

The mean follow-up was 12.1 months (range from 3 to 28 months). Six eyes were complicated by some eye diseases postoperatively. The best-corrected visual acuity was 20/40 or better in other 34 eyes (87.17%). All eyes with secondary IOL fixation presented equal or better naked visual acuity than best-corrected visual acuity best-corrected preoperatively. No intraoperative and postoperative complications such as hemorrhage, retinal detachment, intraocular lens tilt and decentration occurred.

CONCLUSION

Sulcus transscleral intraocular lens suture fixation via small sclera tunnel incision was easy to operate and master, required less operative time, and made primary intraocular lens fixation more effective in eyes with posterior capsule defect or insufficient zonula support in small sclera tunnel incision surgery. In addition, the technique was safe and efficient for secondary intraocular lens fixation.

Для цитирования: Wu Wenjie, Li Qing, Yan Duan, Zhang Jianhui, Chen Yi, Zhang Huiying. Sulcus Transscleral Intraocular Lens Suture Fixation through Small Scleral Tunnel Incision.. Eye science. 2011. DOI: 10.3969/j.issn.1000-4432.2011.02.021.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.