MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20241009-02

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2024

Clinical Comparison of Decentration and Tilt Effects in Iris-Claw and Trans-scleral Plug Lenses: Wavefront Analysis With a Pyramidal Sensor Aberrometer.

de Angelis Lorenzo, Romano Vito, Barbera Giuseppe Ruben, Galasso Mario, Aliò Jorge L, Giansanti Fabrizio, Barca Francesco

СтатьяСравнительное исследованиеНаблюдательное исследованиеПеревод в очереди

Аннотация

PURPOSE: To compare the aberrometric profile of the Artisan Aphakia lens (Opthec BV) and transscleral plug FIL-SSF lens (Soleko) and to assess the impact of tilt and decentration on their optical performance.

METHODS

This retrospective observational study was conducted at Azienda Ospedaliera Universitaria Careggi, Florence, Italy, with a consecutive cohort of aphakic eyes undergoing secondary lens implantation with an Artisan or FIL-SSF lens. Wavefront analysis was performed using a pyramidal wavefront-based aberrometer (Osiris-T; CSO). Tilt and decentration were calculated using anterior segment optical coherence tomography (MS-39; CSO).

RESULTS

The study included 47 eyes from 45 patients: 24 eyes in the FIL-SSF group and 23 eyes in the Artisan group. Decentration was 0.39 ± 0.14 mm in the FIL-SSF group and 0.51 ± 0.16 mm in the Artisan group (P = .02). The mean tilt value was 6.6 ± 2.35 degrees in the FIL-SSF group and 5.9 ± 1.86 degrees in the Artisan group (P = .13). Internal higher order aberrations (HOAs) were 0.23 ± 0.07 μm in the FIL-SSF group and 0.29 ± 0.13 μm in the Artisan group (P = .02). The point spread function (PSF) Strehl ratio was 0.12 ± 0.05 in the FIL-SSF group and 0.10 ± 0.04 (P = .11) in the Artisan group. The PSF Strehl ratio without lower order aberration (PSFw2) was 0.28 ± 0.12 in the FIL-SSF group and 0.23 ± 0.09 in the Artisan group (P = .01).

CONCLUSIONS

The Artisan and FIL-SSF lenses provide comparable optical performance in terms of the PSF Strehl ratio. However, the Artisan lens appears to be more susceptible to decentration, which may result in increased higher order aberrations and a consequently lower PSFw2 Strehl ratio. [J Refract Surg. 2024;40(12):e926-e933.].

Для цитирования: de Angelis Lorenzo, Romano Vito, Barbera Giuseppe Ruben, Galasso Mario, Aliò Jorge L, Giansanti Fabrizio, Barca Francesco. Clinical Comparison of Decentration and Tilt Effects in Iris-Claw and Trans-scleral Plug Lenses: Wavefront Analysis With a Pyramidal Sensor Aberrometer.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2024. DOI: 10.3928/1081597x-20241009-02.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.