Visual performance of a refractive extended depth of field intraocular lens in monovision and emmetropic settings.

Zeilinger Johannes, Ruiss Manuel, Pilwachs Caroline, Georgiev Stefan, Spartalis Christoph, Findl Oliver

СтатьяПеревод в очереди

Аннотация

PURPOSE: To compare visual performance, low-contrast visual acuity, stereopsis, and patient-reported outcomes of a refractive Extended Depth of Field (EDF) intraocular lens (IOL) implanted targeting mini-monovision or emmetropia target.

DESIGN

Prospective, randomized, controlled, patient- and examiner-masked single-center clinical trial.

METHODS

Sixty patients (120 eyes) undergoing bilateral cataract surgery at the Hanusch Hospital (Vienna, Austria) received the refractive EDF intraocular lens (DEN00V, Tecnis PureSee). Patients were randomized to receive either binocular mini-monovision (MMV), targeting -0.75 D in the non-dominant eye, or emmetropia (EMM). Binocular uncorrected and corrected distance visual acuity (UDVA/CDVA), uncorrected intermediate (UIVA) and near visual acuity (UNVA), low contrast visual acuity, defocus curves, stereopsis, and patient-reported outcomes (PRSIQ, AIOLIS) were evaluated three months postoperatively.

RESULTS

Binocular UDVA and CDVA were excellent and did not differ significantly between groups (110 eyes; 55 participants completed follow-up), -0.02±0.07 logMAR for MMV and -0.05±0.07 logMAR for EMM (mean difference: 0.03 logMAR; 95% Confidence Interval -0.01 to 0.07; p=0.14) and -0.05±0.06 logMAR for MMV and -0.09±0.08 logMAR for EMM (0.04 logMAR; 95% CI -0.01 to 0.09; p=0.06), respectively. Binocular UIVA was 0.06±0.08 logMAR for MMV and 0.10±0.09 logMAR for EMM (-0.04 logMAR; 95% CI -0.09 to 0.01; p=0.09) and UNVA 0.20±0.07 logMAR for MMV and 0.23±0.09 logMAR for EMM (-0.03 logMAR; 95% CI -0.08 to 0.02; p=0.18). Low contrast visual acuity was statistically significantly better in the emmetropia group at 5% (0.10 logMAR; 95% CI 0.04 to 0.16; p<0.001) and 1.25% (0.10 logMAR; 95% CI 0.03 to 0.17; p=0.01) levels of contrast after Holm-Bonferroni correction. Binocular defocus curves were comparable with no statistically significant differences after correction for multiple comparisons. Stereopsis was preserved in both groups without significant differences. Patient-reported outcomes demonstrated high satisfaction and low spectacle dependence in both groups for far and intermediate distance, with slightly reduced near spectacle dependence but increased glare in the mini-monovision group.

CONCLUSIONS

Bilateral implantation of the DEN00V, a refractive EDF intraocular lens, in a mini-monovision or emmetropia setting, provides excellent distance and intermediate vision with good low-contrast visual acuity and preserved stereopsis. Applying a mini-monovision strategy preserved good distance vision with compromises in low-contrast visual acuity and subjective visual phenomena.

Для цитирования: Zeilinger Johannes, Ruiss Manuel, Pilwachs Caroline, Georgiev Stefan, Spartalis Christoph, Findl Oliver. Visual performance of a refractive extended depth of field intraocular lens in monovision and emmetropic settings.. American journal of ophthalmology. 2026. DOI: 10.1016/j.ajo.2026.09.009.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.