MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2106/jbjs.26.00619

Медицинская библиотека · The Journal of bone and joint surgery. American volume · 2026

Vancomycin-Loaded Mesh Reduces Staphylococcal Infection in a Murine Extensor Mechanism Reconstruction Model.

Lin Tsung-Li, Bedard Nicholas A, Karau Melissa J, Herren Sebastian C, Patel Robin, Abdel Matthew P

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Infection following extensor mechanism reconstruction (EMR) with Marlex mesh (C.R. Bard) is devastating and limb-threatening. The purpose of this study was to evaluate whether vancomycin-loaded mesh reduces staphylococcal infection in a murine EMR model.

METHODS

Mouse-sized, 8-layer mesh constructs were fabricated to simulate clinical reconstruction and soaked in a vancomycin solution (50 mg/mL) for in vitro and in vivo testing. Three methicillin-resistant clinical isolates from human periprosthetic Staphylococcus aureus, Staphylococcus epidermidis, and Staphylococcus lugdunensis knee infections were evaluated. In vitro testing assessed vancomycin loading capacity, mechanical properties, antibacterial activity, and inhibition of biofilm formation. For in vivo experiments, plain or vancomycin-loaded mesh was implanted into C57BL/6 mouse extensor mechanisms, which were intraoperatively contaminated with 1 of the 3 study isolates (5 per group). Mesh and surrounding tissue were harvested for quantitative culture on postoperative day 9.

RESULTS

For all 3 isolates, vancomycin-loaded mesh produced zones of inhibition and exhibited antibacterial activity through at least 3 days in vitro (p < 0.0001). Mechanical testing revealed that loading mesh with vancomycin did not negatively impact tensile strength, hysteresis, or suture pull-through properties. In vitro testing of inhibition of biofilm formation demonstrated reduced colony-forming units 6 hours after inoculation, which remained low throughout the 9-day experimental period (p < 0.05 for all isolates). In vivo, vancomycin-loaded mesh reduced bacterial burden on mesh and in surrounding tissue by >3 log10 compared with plain mesh for all 3 isolates (p < 0.01 for both mesh and tissue).

CONCLUSIONS

Vancomycin-loaded mesh provided in vitro antibacterial activity without compromising mesh mechanical properties and reduced staphylococcal infection in a murine EMR model. Further work is needed to evaluate translational potential and safety before clinical application.

CLINICAL RELEVANCE: Mesh-associated infection after EMR is devastating and difficult to treat. These preclinical findings suggest that local vancomycin delivery may serve as an adjunct to systemic prophylaxis, warranting further study before clinical use.

Для цитирования: Lin Tsung-Li, Bedard Nicholas A, Karau Melissa J, Herren Sebastian C, Patel Robin, Abdel Matthew P. Vancomycin-Loaded Mesh Reduces Staphylococcal Infection in a Murine Extensor Mechanism Reconstruction Model.. The Journal of bone and joint surgery. American volume. 2026. DOI: 10.2106/jbjs.26.00619.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.