MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ico.0000000000004230

Медицинская библиотека · Cornea · 2026

Early Detection of Keratoconus Using Corneal Tomography Image Analysis by GPT-5.4.

Kapelushnik Noa, Kamar Daniela, Megreli Jacob, Reitblat Olga, Sella Ruti, Bahar Irit, Nahum Yoav, Livny Eitan

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the diagnostic performance and limitations of a general-purpose multimodal large language model (GPT-5.4) in detecting early keratoconus (KC) using corneal tomography images.

METHODS

This retrospective study included 66 eyes: 15 with subclinical KC, 18 with forme fruste keratoconus (ffKC), and 33 normal controls. Control eyes were obtained from refractive surgery candidates with normal corneas. For each eye, a standardized four-map Pentacam tomography image was analyzed using GPT-5.4 (OpenAI) with a predefined prompt. Only images were provided, without clinical or demographic data. Diagnostic performance for detecting early KC was assessed using sensitivity, specificity, predictive values, accuracy, and receiver operating characteristic (ROC) analysis.

RESULTS

GPT-5.4 demonstrated low sensitivity (30.3%) and high specificity (100%) for detecting early KC, with an overall accuracy of 65.2% and an area under the ROC curve of 0.65. The model showed a strong tendency to classify eyes as normal, resulting in a high rate of false-negative classifications. Multiclass analysis revealed a stage-dependent performance pattern, with excellent classification of normal corneas (100%), moderate detection of subclinical KC (53.3%), and poor detection of ffKC (11.1%), with most ffKC cases misclassified as normal.

CONCLUSIONS

GPT-5.4 demonstrates high specificity but limited sensitivity for detecting early KC using image-only input and is not a reliable diagnostic or screening tool in its current form.

Для цитирования: Kapelushnik Noa, Kamar Daniela, Megreli Jacob, Reitblat Olga, Sella Ruti, Bahar Irit, Nahum Yoav, Livny Eitan. Early Detection of Keratoconus Using Corneal Tomography Image Analysis by GPT-5.4.. Cornea. 2026. DOI: 10.1097/ico.0000000000004230.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.