MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2019.04.054

Медицинская библиотека · International journal of cardiology · 2019

Abluminal biodegradable polymer biolimus-eluting versus durable polymer everolimus-eluting stent in patients with diabetes mellitus: 5 years follow-up from the COMPARE II trial.

Paradies Valeria, Vlachojannis Georgios J, Royaards Kees-Jan, Wassing Jochem, van der Ent Martin, Smits Pieter C

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Drug eluting stents with biodegradable polymers have been developed to address the risk of very late adverse events. Long-term comparison data between the biodegradable polymer-coated biolimus-eluting stent (BES; Nobori®) and the second-generation durable polymer-coated everolimus-eluting stent (EES; XIENCE V® or XIENCE PRIME® or PROMUS™) in diabetic patients are scarce.

METHODS

The COMPARE II trial was an investigator-initiated, multicenter, open-label, randomized, all-comers trial which assigned patients undergoing percutaneous coronary intervention (PCI) in a 2:1 fashion to either BES or EES. We analyzed the safety and efficacy outcomes in diabetic patients at 5 year follow-up. The primary pre-specified composite endpoint major adverse cardiac event (MACE) was defined as cardiac death, non-fatal target-vessel myocardial infarction (TV-MI), or clinically indicated target vessel revascularization (CD-TVR).

RESULTS

Out of 2707 study patients, 588 were diabetics (21.7%) of whom 391 were treated with BES and 197 with EES. At 5 years follow-up, MACE occurred in 87 patients (22.2%) in the BES group and in 34 patients (17.2%) in the EES group (p = .34). Other safety and efficacy endpoints did not differ between stent groups.

CONCLUSIONS

At 5 years follow-up, no differences in terms of MACE as well as all analyzed safety and efficacy measures, including stent thrombosis, between the biodegradable polymer-coated BES and the durable polymer-coated EES in diabetic patients were observed.

Для цитирования: Paradies Valeria, Vlachojannis Georgios J, Royaards Kees-Jan, Wassing Jochem, van der Ent Martin, Smits Pieter C. Abluminal biodegradable polymer biolimus-eluting versus durable polymer everolimus-eluting stent in patients with diabetes mellitus: 5 years follow-up from the COMPARE II trial.. International journal of cardiology. 2019. DOI: 10.1016/j.ijcard.2019.04.054.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.