MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/diagnostics16172760

Медицинская библиотека · Diagnostics (Basel, Switzerland) · 2026

Diagnostic Accuracy and Usability of the Pluslife Mycobacterium tuberculosis Assay on Tongue and Sputum Swabs in Symptomatic and Asymptomatic Adults in South Africa.

David Anura, Scott Lesley E, Singh Lyndel, Marokane Puleng, da Silva Manuel P, Gast Danielle, Noble Lara D, Waja Ziyaad, Moloantoa Tumelo, Martinson Neil A, Stevens Wendy

СтатьяПеревод в очереди

Аннотация

Background/

Objectives

Access to accurate tuberculosis (TB) diagnostics remains limited, particularly in high-burden settings. The Pluslife MTB assay is among the first molecular tests specifically designed for swab-based detection of Mycobacterium tuberculosis complex (MTBC) and offers near point-of-care use.

Methods

We conducted a prospective diagnostic accuracy study in South Africa to evaluate the performance of the Pluslife assay on tongue swabs (TSs) and sputum swabs (SSs) among symptomatic and asymptomatic adults. Results were compared against liquid culture as the reference standard and Xpert MTB/RIF Ultra (Xpert Ultra) as a comparator. Operational characteristics and ease-of-use were assessed through structured observation and Likert-scale scoring by testing personnel.

Results

Of the 256 participants enrolled, 92 [36%] were people with HIV (PHIV) and 217 were included in the final analysis. Culture confirmed TB in 41/217 (19%). Pluslife on SSs demonstrated a sensitivity of 85% (95% CI: 70.8-94.4), compared to 83% (95% CI: 67.9-92.8), for Xpert Ultra on sputum and detected one additional case (paired analysis, p = 1.000). Sensitivity on TSs was lower (63%, 95% CI: 46.9-77.9), particularly among PHIV. Specificity exceeded 97% across specimen types. Concordance on TSs between Pluslife and Xpert Ultra increased with higher bacterial loads. Operational evaluation showed short hands-on time and high ease-of-use scores, though limitations were noted for patient identifier recording and troubleshooting on the Pluslife MiniDock device.

Conclusions

The Pluslife MTB assay on SSs demonstrated good diagnostic accuracy and favorable usability in this study. Tongue swabs remain feasible but less reliable, supporting sputum as the preferred first specimen for TB diagnosis.

Для цитирования: David Anura, Scott Lesley E, Singh Lyndel, Marokane Puleng, da Silva Manuel P, Gast Danielle, Noble Lara D, Waja Ziyaad, Moloantoa Tumelo, Martinson Neil A, Stevens Wendy. Diagnostic Accuracy and Usability of the Pluslife Mycobacterium tuberculosis Assay on Tongue and Sputum Swabs in Symptomatic and Asymptomatic Adults in South Africa.. Diagnostics (Basel, Switzerland). 2026. DOI: 10.3390/diagnostics16172760.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.