Endoscopic versus microscopic type-I cartilage tympanoplasty for anterior perforation - a comparative study.

Shakya Dipesh, Kc Arun, Tamang Nirmala, Nepal Ajit

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Chronic otitis media with anterior perforation is a challenging condition to treat with a microscope especially if the canal is narrow or has overhang. The endoscope provides the advantage of wide-angle view and transcanal access avoiding postauricular approach and canaloplasty.

OBJECTIVE

To compare the anatomical, functional outcomes, and surgical duration between endoscopic and microscopic type-I tympanoplasty performed for anterior perforation.

MATERIALS AND

METHODS

A comparative study was conducted. The two groups, the microscopic (MT) and the endoscopic (ET) were created with 50 cases each and underwent type-I tympanoplasty. Results were evaluated at a minimum follow-up of 12 months.

RESULTS

The graft uptake rate in MT and ET was 81.8% and 91.3% respectively and was not statistically significant. The mean operative time for MT and ET was 68.68 ± 18.79 min and 61.24 ± 11.18 min respectively which was significant (p-.003). Endoscopic tympanoplasty significantly saved time. The difference in hearing outcomes was highly significant within the groups but not between the groups.

CONCLUSION AND SIGNIFICANCE: The endoscopic tympanoplasty offered superior visualization avoiding postauricular incision and canaloplasty, with morphological and functional outcomes comparable to microscopic tympanoplasty. It offers significantly faster completion of procedure and provides minimally invasive surgery.

Для цитирования: Shakya Dipesh, Kc Arun, Tamang Nirmala, Nepal Ajit. Endoscopic versus microscopic type-I cartilage tympanoplasty for anterior perforation - a comparative study.. Acta oto-laryngologica. 2020. DOI: 10.1080/00016489.2020.1834616.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.