MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bmjopen-2024-088496

Медицинская библиотека · BMJ open · 2024

Effect of telemonitoring on the rate of dropout during home non-invasive ventilation: a retrospective study using a home care provider database.

Le Mao Raphael, Gut Gobert Christophe, Texereau Joelle B, Kremer Frédérique, Goret Marion, Chekroun Martinot Aurélie, Rosé Mathieu, Trzepizur Wojciech, Gagnadoux Frédéric

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Telemonitoring (TM) of home non-invasive ventilation (NIV) has been shown to facilitate home/outpatient therapy set-up. However, the impact of long-term TM on therapy dropouts, compliance and leak control has not yet been clearly determined. This study evaluated whether the NIV dropout rate was reduced by TM combined with remote patient support compared with a non-telemonitoring (NTM) pathway.

DESIGN

Retrospective cohort study.

SETTING

Data were obtained from all agencies of a single home care provider in France.

PARTICIPANTS

Adults with chronic respiratory failure (n=659) who started nocturnal NIV between January 2017 and December 2019 and had ≥8 days of NIV therapy (51% male; mean age 68.5±13.8 years; 35.5% on long-term oxygen therapy) were included. The TM group included 275 patients who spent ≥80% of the follow-up using TM, and the NTM group included 384 patients who had 0 to ≤10 days of telemonitoring during follow-up.

PRIMARY AND SECONDARY OUTCOME MEASURES: The primary outcome was the rate of NIV dropouts at 1 year (ie, treatment discontinuation, excluding deaths). Secondary outcomes included therapy compliance and leaks.

RESULTS

82 patients died during follow-up. Significantly fewer patients in the TM vs NTM group had dropped out of NIV therapy at 1 year (13% vs 34%; p<0.001). After adjustment for age, sex, NIV usage at 1-month follow-up and the main underlying respiratory disease, TM was significantly associated with a lower risk of dropout (HR 0.33, 95% CI 0.23 to 0.49; p<0.001). At 1, 4, 8 and 12 months, a greater proportion of patients in the TM vs NTM group had NIV usage of >4 hours/day and control of leaks.

CONCLUSIONS

In patients starting home NIV, TM with home care provider first-line support was associated with a lower therapy dropout rate at 1 year, and better compliance and leak control, compared with standard follow-up.

Для цитирования: Le Mao Raphael, Gut Gobert Christophe, Texereau Joelle B, Kremer Frédérique, Goret Marion, Chekroun Martinot Aurélie, Rosé Mathieu, Trzepizur Wojciech, Gagnadoux Frédéric. Effect of telemonitoring on the rate of dropout during home non-invasive ventilation: a retrospective study using a home care provider database.. BMJ open. 2024. DOI: 10.1136/bmjopen-2024-088496.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.