m+Medelevator.RU
← Поиск публикаций
EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2025

TAVI with the ACURATE neo2 in severe bicuspid aortic valve stenosis: the Neo2 BAV Registry.

СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ruck Andreas, Kim Won-Keun, Del Sole Paolo Alberto, Wagener Max, McInerney Angela, Yacoub Magdi S, Hasabo Elfatih A, Ayhan Cagri, Elzomor Hesham, Neiroukh Dina, Amir Abdul, Saleh Nawzad, Settergren Magnus, Lindler Rickard, Verouhis Dinos, Sossalla Samuel, Renker Matthias, Montorfano Matteo, Bellini Barbara, Suarez Xavier Carrillo, Del Olmo Victoria Vilalta, De Marco Federico, Biroli Matteo, Mollmann Helge, Enno Eckel Clemens, Tarantini Giuseppe, Fabris Tommaso, Ielasi Alfonso, Costa Giuliano, Barbanti Marco, Soliman Osama, Mylotte Darren

Аннотация

BACKGROUND: The ACURATE neo2 is a contemporary transcatheter aortic valve implantation (TAVI) system approved for the treatment of severe aortic stenosis in Europe. The ACURATE neo2 has not been evaluated in bicuspid aortic valve (BAV) stenosis.

AIMS: We sought to evaluate the safety and efficacy of ACURATE neo2 in patients with BAV stenosis.

METHODS: We retrospectively analysed consecutive severe BAV stenosis patients undergoing TAVI with ACURATE neo2 at 10 European centres. Imaging data from preprocedural multislice computed tomography, pre- and postprocedural echocardiography, and procedural cinefluoroscopy were evaluated by a core laboratory. Valve Academic Research Consortium 3 (VARC-3)-defined 30-day procedure safety and efficacy were the primary endpoints. Adverse events were site-reported according to VARC-3 criteria.

RESULTS: Among 181 patients with BAV stenosis treated with the ACURATE neo2, the mean age was 77.5±7.2 years, 58.0% were female, and the Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) score was 2.3% (1.6-3.7%). Most procedures were transfemoral, and predilatation was performed in all cases. A second valve was required in 4 cases (2.2%). VARC-3-defined technical success was 95.6%. The primary endpoints of device success and early safety occurred in 90.6% and 82.3%, respectively. At 30 days, cardiovascular death occurred in 2.2% (N=4) and stroke in 1.6% (N=3). Core laboratory-adjudicated echocardiography reported an effective orifice area of 2.0 (1.7-2.5) cm2 and a mean transvalvular gradient of 6.5 (4.6-9.0) mmHg. Half of all cases (51.2%) had no paravalvular leak, while moderate leak occurred in 4.3%. A new permanent pacemaker was required in 11 patients (6.5%).

CONCLUSIONS: The ACURATE neo2 demonstrated favourable clinical outcomes and bioprosthetic valve performance at 30 days in selected patients with severe BAV stenosis.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты