Sato Yoshiki, Takeuchi Kazuhito, Ohka Fumiharu, Nagata Yuichi, Maeda Sachi, Matsuyama Tomoki, Hirose Toshiaki, Deguchi Shoichi, Okumura Eriko, Iwami Kenichiro, Saito Ryuta

Аннотация

BACKGROUND: Corticotroph pituitary neuroendocrine tumors (PitNETs) causing Cushing's disease require complete surgical resection to achieve endocrinological remission. Although endoscopic transsphenoidal surgery is the standard first-line treatment, accurate intraoperative delineation of tumor boundaries remains challenging because the pseudocapsule is often thin or ill-defined and tumor cells may infiltrate adjacent tissues. Given that intraoperative histopathology and conventional molecular methods are limited by time constraints, rapid molecular detection of tumor-specific mutations may serve as an intraoperative surrogate marker for tumor cell presence.

NEW METHOD: We employed a microfluidic real-time PCR platform (GeneSoC®) capable of detecting mutations within a short timeframe for intraoperative molecular boundary diagnosis of corticotroph PitNETs.

RESULTS: Sanger sequencing of archival frozen samples identified the USP8 P720R mutation, which was used to validate the real-time PCR assay. Using a fluorescence intensity cutoff value of 20, real-time PCR reliably discriminated mutation-positive from mutation-negative samples and detected mutations at variant allele frequencies of ≥ 2%. Intraoperatively, four samples obtained from different anatomical sites were analyzed, and real-time PCR detected the USP8 P720R mutation in all samples.

COMPARISON WITH EXISTING METHODS: Real-time PCR rapidly provided diagnostic accuracy comparable to that of immunohistochemistry, Sanger sequencing, and droplet digital PCR. In one sample, the real-time PCR result was discordant with the hematoxylin and eosin staining findings.

CONCLUSIONS: Real-time PCR may serve as a rapid and objective method for intraoperative molecular boundary assessment of corticotroph PitNETs, although further validation is required. This method could potentially be extended to other tumors harboring detectable genetic mutations.