MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jocd.70932

Медицинская библиотека · Journal of cosmetic dermatology · 2026

Evaluation of a Novel Bimodal-Approach Radiofrequency Device for Lower Facial Tightening in Southeast Asian Patients: An Open-Label Prospective Study.

Chottawornsak Natcha, Punthitra Veerarat, Kusonjai Dhanyadhorn, Prinyaroj Nayanunt, Kumar Narendra

СтатьяКлиническое исследованиеПеревод в очереди

Аннотация

BACKGROUND

Radiofrequency (RF) devices are employed for noninvasive facial rejuvenation. A novel bimodal RF system delivers monopolar and bipolar energy sequentially within a single shot to enhance efficacy and safety.

OBJECTIVES

To evaluate the safety and efficacy of a bimodal-RF device, DENSITY Noir (Jeisys Med Inc., Seoul, Republic of Korea), for the treatment of lower facial laxity.

METHODS

This prospective, open-label clinical study enrolled 26 adults (n = 26; 30-60 years) with mild-to-moderate lower facial laxity. All participants received a single RF treatment session with DENSITY Noir. Outcomes were assessed using investigator and participant global assessments, the Facial Laxity Rating Scale, and 3D Antera imaging for nasolabial fold parameters, together with texture and brown spot measured by VISIA. Safety and tolerability were monitored throughout the study. Statistical analyses included Friedman and Wilcoxon tests, marginal homogeneity tests, and linear mixed-effects model tests.

RESULTS

Twenty-three (n = 23) participants completed follow-up. Nearly half (47.83%) achieved marked improvement (51%-75%) on the 6-point global improvement scale at 6 months. Facial laxity ratings significantly improved at 1, 3, and 6 months vs. baseline (p < 0.001). Antera analysis confirmed significant reductions in nasolabial fold cross-sectional area (baseline: 41.94; 1 month: 38.87; 3 months: 39.63; 6 months: 35.72; p = 0.02) and wrinkle width (baseline: 1.98 mm; 6 months: 1.85 mm; p = 0.01). About 78% of participants reported high satisfaction at 6 months. Adverse effects included transient erythema (96.15%), edema (61.53%), and mild procedural pain; all adverse events were minor, transient, and self-limiting.

CONCLUSIONS

DENSITY Noir was associated with significant improvement in lower facial laxity with a favorable safety and tolerability profile in this cohort. Further controlled studies are warranted to confirm efficacy and durability.

TRIAL REGISTRATION: ClinicalTrials.gov identifier: TCTR20250924004.

Для цитирования: Chottawornsak Natcha, Punthitra Veerarat, Kusonjai Dhanyadhorn, Prinyaroj Nayanunt, Kumar Narendra. Evaluation of a Novel Bimodal-Approach Radiofrequency Device for Lower Facial Tightening in Southeast Asian Patients: An Open-Label Prospective Study.. Journal of cosmetic dermatology. 2026. DOI: 10.1111/jocd.70932.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.