The effect of induced monocular blur on measures of stereoacuity.

Odell Naomi V, Hatt Sarah R, Leske David A, Adams Wendy E, Holmes Jonathan M

Клиническое исследованиеСтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод в очереди

Аннотация

PURPOSE: To determine the effect of induced monocular blur on stereoacuity measured with real depth and random dot tests.

METHODS

Monocular visual acuity deficits (range, 20/15 to 20/1600) were induced with 7 different Bangerter filters (<0.1, 0.1, 0.2, 0.3, 0.4, 0.8, and 1.0) in 15 visually normal adults. Stereoacuity was measured with Frisby and Frisby Davis Distance (FD2) real depth tests and Preschool Randot (PSR) and Distance Randot (DR) random dot tests. Stereoacuity results were grouped as either "fine" (<or=60 arcsec), "moderate" (>60 and <or=200 arcsec), or "coarse/nil" (>200 arcsec to nil) stereo.

RESULTS

Across visual acuity deficits, stereoacuity was more severely degraded with random dot (PSR, DR) than with real depth (Frisby, FD2) tests. Degradation to worse-than-fine stereoacuity consistently occurred at 0.7 logMAR (20/100) or worse for Frisby, 0.1 logMAR (20/25) or worse for PSR, and 0.1 logMAR (20/25) or worse for FD2. There was no meaningful threshold for the DR because worse-than-fine stereoacuity was associated with -0.1 logMAR (20/15). Course/nil stereoacuity was consistently associated with 1.2 logMAR (20/320) or worse for Frisby, 0.8 logMAR (20/125) or worse for PSR, 1.1 logMAR (20/250) or worse for FD2, and 0.5 logMAR (20/63) or worse for DR.

CONCLUSIONS

Stereoacuity thresholds are more easily degraded by reduced monocular visual acuity with the use of random dot tests (PSR and DR) than real depth tests (Frisby and FD2). We have defined levels of monocular visual acuity degradation associated with fine and nil stereoacuity. These findings have important implications for testing stereoacuity in clinical populations.

Для цитирования: Odell Naomi V, Hatt Sarah R, Leske David A, Adams Wendy E, Holmes Jonathan M. The effect of induced monocular blur on measures of stereoacuity.. Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus. 2008. DOI: 10.1016/j.jaapos.2008.09.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.