MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1089/ten.tea.2023.0155

Медицинская библиотека · Tissue engineering. Part A · 2023

Effect of Cell Density of a Methacrylic Acid-Based Hydrogel Implant on Embedded Islet Function and Viability.

Ortaleza Krystal, Sefton Michael V

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Subcutaneous delivery of islets in a methacrylic acid-based hydrogel may offer a functional cure for type 1 diabetes. Here we show in mice that the hydrogel is able to provide sufficient vasculature to support islet function and viability, when islets are used at a low islet volume fraction (i.e., cell density). The Krogh cylinder model was used to mathematically estimate the effect of implant volume, for a fixed islet dose (600 islet equivalents [IEQ]), on the minimum vessel density required to maintain sufficient pO2 within the graft. Modeling suggested that 200 μL implants would have low enough islet densities and enough vessels to have islets remain viable, but that 50 μL implants would not; this was confirmed experimentally through measurement of glucose level in streptozotocin-induced diabetic severe combined immunodeficiency disease (SCID/bg) mice, comparing 200 and 50 μL implants, both with 600 IEQ. Vessel densities were ∼20-30 vessels/mm2 independent of implant volume and vessels were sufficient to increase subcutaneous oxygen tension, as measured with microcapsules containing oxygen sensitive material (a platinum [Pt] porphyrin); both these results were determined without cells. These results are useful in thinking about the scale-up of this system to humans: to maintain a low islet density (∼0.5%), many more islets will require attention to the subcutaneous implant configuration to satisfy the oxygen needs of the cells.

Для цитирования: Ortaleza Krystal, Sefton Michael V. Effect of Cell Density of a Methacrylic Acid-Based Hydrogel Implant on Embedded Islet Function and Viability.. Tissue engineering. Part A. 2023. DOI: 10.1089/ten.tea.2023.0155.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.