MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10792-025-03416-6

Медицинская библиотека · International ophthalmology · 2025

Three-dimensional semi-autotamatic segmentation of nasolacrimal duct morphometry on computed tomography images.

Pence Kadriye Betul, Bozkurt Nureda Nalcaci, Tekin Bahar, Sen Selva, Ansen Gamze, Ormeci Tugrul, Yuzbasioglu Neslihan

СтатьяПеревод в очереди

Аннотация

PURPOSE: Given the potential role of nasolacrimal duct (NLD) morphometry in the aetiology of primary acquired obstructions, it is imperative that clinicians have access to detailed anatomical information. The aim of this study was to determine normative data on nasolacrimal duct morphometry in the Turkish population sample and to provide guidelines for clinicians.

METHODS

The study included retrospectively computed tomography images of a healthy Turkish population sample of 151 individuals, 79 of whom were female and 72 of whom were male. Images were modeled and analyzed using 3D Slicer version 5.2.2.

RESULTS

The total volume and area of the NLD were smaller in females than in males. The right- and left-sided volume of the NLD were smaller in females than in males (In male, right side 219.28 ± 77.53 mm3 and left side 213.14 ± 73.82 mm3; in female, right side 193.82 ± 75.71 mm3, left side, 190.34 ± 82.54 mm3). Although the anteroposterior and transverse diameters of the right-sided NLD were not statistically different between the genders, the anteroposterior and transverse diameters of the left-sided NLD and distance between right and left NLD were smaller in female than in males. The volume and surface area of the right-sided NLD and the distance between the right and left NLD were larger with increasing age. The anteroposterior diameter was observed to be larger on the right side than on the left in both sexes, whereas the transverse diameter was larger on the right side than on the left side exclusively in females.

CONCLUSION

The results of this study may assist clinicians in the surgical approaches.

Для цитирования: Pence Kadriye Betul, Bozkurt Nureda Nalcaci, Tekin Bahar, Sen Selva, Ansen Gamze, Ormeci Tugrul, Yuzbasioglu Neslihan. Three-dimensional semi-autotamatic segmentation of nasolacrimal duct morphometry on computed tomography images.. International ophthalmology. 2025. DOI: 10.1007/s10792-025-03416-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.