MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/md.0000000000048988

Медицинская библиотека · Medicine · 2026

Artificial intelligence in contrast-induced nephropathy after coronary interventions: A meta-analysis.

Keetha Narsimha Rao, Contreras Rafael, Saberian Parsa, Hoteit Mayssaa, Nasrollahizadeh Amir, Sonde Darshan Madhav, Hashemi Seyyed Mohammad, Parackal Vishal, Fatehi Hassanabad Ali, Amini-Salehi Ehsan, Samethadka Nayak Sandeep, Gurram Anoop

СтатьяМетаанализПеревод в очереди

Аннотация

BACKGROUND

Contrast-induced nephropathy (CIN) is a major complication following coronary interventions, contributing to increased morbidity and healthcare costs. Machine learning (ML) models provide innovative approaches for predicting CIN by integrating complex clinical variables, potentially improving risk stratification and patient outcomes. This meta-analysis evaluates the predictive performance of ML models for CIN, focusing on the best-performing models.

METHODS

Seventeen studies encompassing 21,69,263 patients were analyzed. The predictive accuracy of ML models was synthesized using pooled area under the curve (AUC) estimates and heterogeneity metrics.

RESULTS

The pooled incidence of CIN was 11% (95% CI: 9-13%). Overall, ML models achieved a pooled AUC of 0.74 (95% CI: 0.72-0.75). Random forest (RF) model demonstrated the highest performance with an AUC of 0.86 (95% CI: 0.85-0.87), followed by gradient boosting machines (GBM) and Extreme Gradient Boosting (XGBoost), both achieving an AUC of 0.79. In training datasets, RF and XGBoost achieved the highest AUCs of 0.98 (95% CI: 0.97-0.99), with GBM following at 0.88 (95% CI: 0.85-0.90). In test datasets, Ensemble models achieved the best performance with an AUC of 0.80 (95% CI: 0.66-0.94), followed by RF and XGBoost with AUCs of 0.75. External validation results showed an overall pooled AUC of 0.77 (95% CI: 0.71-0.84), indicating strong generalizability of the models. Among CIN definitions, the European Society of Urogenital Radiology (ESUR) criteria yielded the best predictive performance, with an AUC of 0.77 (95% CI: 0.72-0.82).

CONCLUSION

RF, Ensemble models, and XGBoost emerged as the most effective ML models for predicting CIN, with RF showing consistent superiority in training datasets and Ensemble models excelling in test datasets. The pooled CIN incidence emphasizes the clinical burden, and the ESUR definition provided the highest predictive accuracy, supporting its utility in CIN risk stratification.

Для цитирования: Keetha Narsimha Rao, Contreras Rafael, Saberian Parsa, Hoteit Mayssaa, Nasrollahizadeh Amir, Sonde Darshan Madhav, Hashemi Seyyed Mohammad, Parackal Vishal, Fatehi Hassanabad Ali, Amini-Salehi Ehsan, Samethadka Nayak Sandeep, Gurram Anoop. Artificial intelligence in contrast-induced nephropathy after coronary interventions: A meta-analysis.. Medicine. 2026. DOI: 10.1097/md.0000000000048988.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.