MedElevator Войти в исследования
← Поиск публикаций

DOI 10.64898/2026.09.16.752110

Медицинская библиотека · bioRxiv : the preprint server for biology · 2026

Quantitative Gait Analysis in a Sheep Model of In-Utero Spina Bifida Repair.

Chou Tsung-Yeh, Pandiri Shreya, Zandiyeh Payam, Figueroa Fernandez Luis A, Lai Dejian, Papanna Ramesha, Mann Lovepreet K

СтатьяПрепринтПеревод в очереди

Аннотация

OBJECTIVE

To evaluate quantitative gait analysis in a sheep model (Ovis aries) of in-utero spina bifida repair.

METHOD: Using a 3D marker-based motion capture system, we quantified spatiotemporal gait parameters and hindlimb joint angles in a sheep model of in-utero spina bifida repair and normal controls. A linear support vector machine classifier, trained and tested on subject-disjoint partitions with individual gait cycles as the unit of analysis, evaluated the relationship between hindlimb joint angles and clinician-assigned Texas Spinal Cord Injury Scale scores. Linear mixed-effects models compared spatiotemporal parameters, hoof height, and hip drop across 3- to 6-month evaluations and between groups.

RESULTS

In treated (n=14) and control (n=3) lambs, front- and hindlimb gait speed differed by timepoint (both p=0.025). Across 1,632 left and 1,661 right hindlimb gait cycles, held-out classification accuracy was 85.9% and 88.6% (Cohen's κ=0.78 and 0.84) for left and right hindlimbs, respectively, against majority-class proportions of 76.5% and 75%. Left hindlimb hip drop differed between treated lambs and controls (Δ=0.8 cm, p=0.027). Between-group contrasts were considered exploratory given the small control group.

CONCLUSION

Quantitative gait analysis was feasible in an in-utero spina bifida repair model. Hindlimb kinematic profiles classified clinical ambulation scores above the majority-class baseline.

Для цитирования: Chou Tsung-Yeh, Pandiri Shreya, Zandiyeh Payam, Figueroa Fernandez Luis A, Lai Dejian, Papanna Ramesha, Mann Lovepreet K. Quantitative Gait Analysis in a Sheep Model of In-Utero Spina Bifida Repair.. bioRxiv : the preprint server for biology. 2026. DOI: 10.64898/2026.09.16.752110.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.