A retrospective study of a new n-butyl-2-cyanoacrylate glue ablation catheter incorporated with application guiding light for the treatment of venous insufficiency: Twelve-month results.

Yavuz Turhan, Acar Altay Nihat, Aydın Huseyin, Ekingen Evren

СтатьяПеревод в очереди

Аннотация

Objective This study aims to present the early results of a retrospective study of the use of novel n-butyl-2-cyanoacrylate (VenaBlock)-based nontumescent endovenous ablation with a guiding light for the treatment of patients with varicose veins. Methods Patients with lower limb venous insufficiency were treated with n-butyl-2-cyanoacrylate (VenaBlock Venous Closure System) between April 2016 and July 2016. The study enrolled adults aged 21-70 years with symptomatic moderate to severe varicosities (C2-C4b) and great saphenous vein reflux lasting longer than 0.5 s with great saphenous vein diameter between 5.5 and 15 mm assessed in the standing position. No compression stockings were used after the procedure. Duplex ultrasound imaging and clinical follow-up were performed on the third day, first month, sixth month, and 12th month. Clinical, etiological, anatomical, pathophysiological classification; venous clinical severity score; and completed Aberdeen varicose vein questionnaire were recorded. Results Five hundred thirty-eight patients with great saphenous vein incompetency underwent n-butyl-2-cyanoacrylate ablation. The mean ablation length was 25.69 ± 4.8 cm, and the average amount of n-butyl-2-cyanoacrylate delivered was 0.87 ± 0.15 ml. The mean procedure time was 11.7 ± 4.9 min. Procedural success was 100%, and complete occlusion was observed after treatment and at the third-day follow-up. We observed ecchymosis in five patients (1.00%) at the entry site at the third-day follow-up. Phlebitis was encountered with six (1.20%) patients. No skin pigmentation, hematoma, paresthesia, deep vein thrombosis, or pulmonary embolism was observed. Kaplan-Meier analysis yielded an occlusion rate of 99.4% at the 12-month follow-up. All patients had significant improvement in venous clinical severity score and Aberdeen varicose vein questionnaire scores postoperatively ( p <0.0001). Venous clinical severity score scores decreased from 5.43 ± 0.87 to 0.6 ± 0.75. Aberdeen varicose vein questionnaire scores decreased from 18.32 ± 5.24 to 4.61 ± 1.42. Conclusions The procedure appears to be feasible, safe, and efficient in treating the great majority of incompetent great saphenous veins with this technique.

Для цитирования: Yavuz Turhan, Acar Altay Nihat, Aydın Huseyin, Ekingen Evren. A retrospective study of a new n-butyl-2-cyanoacrylate glue ablation catheter incorporated with application guiding light for the treatment of venous insufficiency: Twelve-month results.. Vascular. 2018. DOI: 10.1177/1708538118770548.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.