m+Medelevator.RU
← Поиск публикаций
The British journal of ophthalmology · 2025

Advanced imaging of corneal neovascularisation with a novel swept-source AS-OCTA system.

СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lucchino Luca, Vaccaro Sabrina, Airaldi Matteo, Forbice Eliana, Moramarco Antonio, Lambiase Alessandro, Fontana Luigi, Semeraro Francesco, Romano Vito

Аннотация

AIMS: To explore the clinical application of a novel swept-source anterior segment optical coherence tomography angiography (AS-OCTA) system for imaging corneal neovascularisation (CoNV), assessing limbal vasculature and detecting short-term vascular changes following pharmacologic vasoconstriction.

METHODS: This cross-sectional observational study included 20 eyes: 10 with clinically diagnosed CoNV of various aetiologies and 10 healthy controls. Each eye underwent AS-OCTA imaging using the BMizar 400kHz Full-Range Swept-Source OCT system at baseline and after administration of 10% phenylephrine (PE). FlowArea (mm2) was automatically calculated across predefined circular regions of interest (ROIs) encompassing the cornea, limbus and episclera. In corneal and limbal ROIs, en face images were segmented into three depth layers: total (epithelium to endothelium), superficial (epithelium to 150 µm) and deep (150 µm to endothelium).

RESULTS: CoNV eyes exhibited significantly higher total and deep corneal FlowArea compared with controls (p=0.0002 and p=0.0005, respectively). Post PE, a significant reduction in FlowArea was observed in the total and deep corneal layers of CoNV eyes (p=0.006 and p=0.009, respectively), and in the limbal region of both groups, with significant reductions observed in CoNV and controls (p=0.006 and p=0.003, respectively).

CONCLUSIONS: This AS-OCTA platform enabled high-resolution, depth-resolved visualization of CoNV and revealed vascular changes following topical vasoconstriction. The extended field of view allowed simultaneous assessment of corneal, limbal and episcleral vasculature within a single scan session, supporting its potential role in both diagnostic evaluation and longitudinal monitoring of anterior segment diseases.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты