MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.joa.2014.09.003

Медицинская библиотека · Journal of arrhythmia · 2014

Defibrillation lead placement using a transthoracic transatrial approach in a case without transvenous access due to lack of the right superior vena cava.

Otsuka Yosuke, Okamura Hideo, Sato Syunsuke, Nakajima Ikutaro, Ishibashi Kohei, Miyamoto Kouji, Noda Takashi, Aiba Takeshi, Kamakura Shiro, Kobayashi Junjiro, Yasuda Satoshi, Ogawa Hisao, Kusano Kengo

СтатьяПеревод в очереди

Аннотация

A 65-year-old woman with a history of syncope was diagnosed with hypertrophic cardiomyopathy. She had previously undergone mastectomy of the left breast owing to breast cancer. Holter electrocardiogram (ECG) and monitor ECG revealed sick sinus syndrome (Type II) and non-sustained ventricular tachycardia. Sustained ventricular tachycardia and ventricular fibrillation were induced in an electrophysiological study. Although the patient was eligible for treatment with a dual chamber implantable cardioverter defibrillator (ICD), venography revealed lack of the right superior vena cava (R-SVC). Lead placement from the left subclavian vein would have increased the risk of lymphedema owing to the patient׳s mastectomy history. Consequently, the defibrillation lead was placed in the right ventricle by direct puncture of the right auricle through the tricuspid valve. The atrial lead was sutured to the atrial wall, and the postoperative course was unremarkable. Defibrillation lead placement using a transthoracic transatrial approach can be an alternative method in cases where a transvenous approach for lead placement is not feasible.

Для цитирования: Otsuka Yosuke, Okamura Hideo, Sato Syunsuke, Nakajima Ikutaro, Ishibashi Kohei, Miyamoto Kouji, Noda Takashi, Aiba Takeshi, Kamakura Shiro, Kobayashi Junjiro, Yasuda Satoshi, Ogawa Hisao, Kusano Kengo. Defibrillation lead placement using a transthoracic transatrial approach in a case without transvenous access due to lack of the right superior vena cava.. Journal of arrhythmia. 2014. DOI: 10.1016/j.joa.2014.09.003.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.