DOI 10.1097/mao.0000000000001212

Медицинская библиотека · Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2016

The Effect of Piston Diameter in Stapedotomy for Otosclerosis: A Temporal Bone Model.

Wegner Inge, Eldaebes Mostafa M A S, Landry Thomas G, Grolman Wilko, Bance Manohar L

СтатьяПеревод в очереди

Аннотация

HYPOTHESIS: The use of larger-diameter pistons in stapedotomy leads to better hearing outcomes compared with the use of smaller-diameter pistons. There is an interaction between stapes piston diameter and fenestration diameter.

BACKGROUND

Otosclerosis can be treated surgically by removing part of the stapes and bypassing the stapes footplate with a prosthesis. Available piston shaft diameters range between 0.3 and 0.8 mm. There has been a tendency toward the use of smaller-diameter pistons, because of a suspected decreased risk of cochlear trauma and subsequent sensorineural hearing loss (SNHL) with smaller pistons. However, mathematical models, temporal bone studies, and clinical studies suggest that the use of larger-diameter pistons is associated with better hearing outcomes.

METHODS

Three fresh-frozen, non-pathologic temporal bones were harvested from human cadaveric donors. Acoustic stimuli in the form of pure tones from 250 to 8000 Hz were generated at 110 dB sound pressure level. A total of 16 frequencies in a 1/3-octave series were used. Stapes and round window velocities in response to the acoustic stimuli were measured at multiple equally spaced points covering the stapes footplate and round window using a scanning laser Doppler interferometry system. Eight sets of measurements were performed in each temporal bone: 1) normal condition (mobile stapes), 2) stapes fixation and stapedotomy followed by insertion of 3) a 0.4-mm-diameter piston in a 0.5-mm-diameter fenestration, 4) a 0.4-mm-diameter piston in a 0.7-mm-diameter fenestration, 5) a 0.4-mm-diameter piston in a 0.9-mm-diameter fenestration, 6) a 0.6-mm-diameter piston in a 0.7-mm-diameter fenestration, 7) a 0.6-mm-diameter piston in a 0.9-mm-diameter fenestration, and 8) a 0.8-mm-diameter piston in a 0.9-mm-diameter fenestration.

RESULTS

At midrange frequencies, between 500 and 4000 Hz, round window velocities increased by 2 to 3 dB when using a 0.6-mm-diameter piston compared with a 0.4-mm-diameter piston. Using a 0.8-mm-diameter piston led to a further increase in round window velocities by 2 to 4 dB.

CONCLUSION

Our results suggest a modest effect of piston diameter on hearing results following stapedotomy.

Для цитирования: Wegner Inge, Eldaebes Mostafa M A S, Landry Thomas G, Grolman Wilko, Bance Manohar L. The Effect of Piston Diameter in Stapedotomy for Otosclerosis: A Temporal Bone Model.. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2016. DOI: 10.1097/mao.0000000000001212.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.