DOI 10.61622/rbgo/2025rbgo52

Медицинская библиотека · Revista brasileira de ginecologia e obstetricia : revista da Federacao Brasileira das Sociedades de Ginecologia e Obstetricia · 2025

Voiding urodynamics parameters for women with and without symptomatic pelvic organ prolapse.

Martins José Tadeu Carvalho, Marquini Gisele Vissoci, de Abreu Laura Aparecida Xavier, Bella Zsuzsanna Ilona Katalin de Jármy Di, Sartori Marair Gracio Ferreira

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

This study aims to characterize voiding urodynamics parameters suggestive of bladder outlet obstruction (BOO) diagnosis in women with and without symptomatic pelvic organ prolapse (POP).

METHODS

Cross-sectional research. Patients were selected and clinically evaluated with anamnesis, pelvic organ prolapse quantification system and standard Urodynamic Testing, performed according to International Continence Society and International Urogynecological Association guidelines (noninvasive uroflowmetry, followed by invasive cystometry and a Pressure/Flow Study). Included criteria: women aged 18 to 94 years with and without symptomatic POP and lower urinary tract symptoms . Exclusion criteria: patients who were not clinically feasible, undesirable, or impossible urodynamic test, or patients with urinary tract infection or neurological lower urinary tract dysfunction.

RESULTS

Voiding urodynamics parameters suggestive of BOO diagnosis found in women with POP were: maximum flow rate (Qmax) in the uroflowmetry ≤12mL/s; detrusor pressure at maximum flow (PdetQmax) >20cmH2O. When evaluating the differences between patients with and without POP, it was observed that those who presented some type of pPOP were mean age (y) older (67.6 × 58.9); had higher post-void residue volume (mL) (85.9 × 33.9); higher PdetQmax (cmH2O) values (41.3 × 28.5); lower Qmax (mL/s) values on uroflowmetry (8.5 × 20.4), lower maximum cystometric capacity (mL) (325.7 × 381.2), lower bladder compliance (mL/cmH2O) (39.8 × 46.1) and lower Qmax (mL/cmH2O) in the flow/pressure study (8.4 × 18.0) (p<0.001).

CONCLUSION

The voiding urodynamics parameters listed in this study allows the evaluation of variables suggestive of BOO diagnosis in women with and without POP.

Для цитирования: Martins José Tadeu Carvalho, Marquini Gisele Vissoci, de Abreu Laura Aparecida Xavier, Bella Zsuzsanna Ilona Katalin de Jármy Di, Sartori Marair Gracio Ferreira. Voiding urodynamics parameters for women with and without symptomatic pelvic organ prolapse.. Revista brasileira de ginecologia e obstetricia : revista da Federacao Brasileira das Sociedades de Ginecologia e Obstetricia. 2025. DOI: 10.61622/rbgo/2025rbgo52.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.