MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circinterventions.125.015325

Медицинская библиотека · Circulation. Cardiovascular interventions · 2025

Early Outcomes of Self-Expandable Versus Balloon-Expandable Valves for Managing Dysfunctional Right Ventricular Outflow Tracts.

Haddad Raymond N, Rouau Quentin, Albenque Grégoire, Cohen Sarah, Radojevic Jelena, Valdeolmillos Estibaliz, Guirgis Lisa, Fournier Emmanuelle, Chevalet Valentin, Belli Emre, Petit Jérôme, Ladouceur Magalie, Batteux Clément, Hascoët Sébastien

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Self-expandable valves are emerging complements to balloon-expandable valves for transcatheter pulmonary valve replacement in dysfunctional right ventricular outflow tracts, though their safety and efficacy remain underexplored. We aim to compare patient characteristics and outcomes of self-expandable valves and balloon-expandable valves in transcatheter pulmonary valve replacement.

METHODS

Baseline and early follow-up data were prospectively analyzed for 145 patients who underwent transcatheter pulmonary valve replacement with Edwards SAPIEN 3 (ES3) balloon-expandable valves or Venus-P self-expandable valves (January 2022-December 2024). An independent adjudication expert analyzed and classified adverse events.

RESULTS

Cohort: 58.6% males, median weight of 65 kg, median age of 36.3 years; 64.1% of ES3, 35.9% of Venus-P. Tetralogy of Fallot was present in 55.2%, with native/patched right ventricular outflow tracts in 41.9% of ES3 and 100% of Venus-P cases (P<0.001). Severe pulmonary regurgitation was found in 64.5% of ES3 and 100% of Venus-P (P<0.001). Median valve diameter was 26 mm (Q1-Q3: 23-29) for ES3 and 36 mm (32-36) for Venus-P (P<0.001). All implantations were successful, with no significant difference in procedure or fluoroscopy times between groups. Postoperative median right ventricular outflow tract maximum velocity was 2.2 m/s (1.9-2.6) for ES3 and 1.6 m/s (1.1-1.8) for Venus-P (P<0.001). Procedural and vascular-access adverse events occurred in 14 patients (ES3: 9.7%, Venus-P: 9.6%; P=0.992), including 8 moderate and 1 major (ES3: 5.4%, Venus-P: 7.7%; P=0.582). New-onset ventricular arrhythmias occurred in 14 patients (ES3: 3.2%, Venus-P: 21.1%; P<0.001), including 5 classified as moderate adverse events, all in Venus-P (P=0.002). All arrhythmias resolved with short-term therapy; no permanent antiarrhythmics or ablations were needed.

CONCLUSIONS

Self-expandable valves are effective for transcatheter pulmonary valve replacement but linked to higher transient arrhythmic adverse event rates than balloon-expandable valves in the early postoperative period.

Для цитирования: Haddad Raymond N, Rouau Quentin, Albenque Grégoire, Cohen Sarah, Radojevic Jelena, Valdeolmillos Estibaliz, Guirgis Lisa, Fournier Emmanuelle, Chevalet Valentin, Belli Emre, Petit Jérôme, Ladouceur Magalie, Batteux Clément, Hascoët Sébastien. Early Outcomes of Self-Expandable Versus Balloon-Expandable Valves for Managing Dysfunctional Right Ventricular Outflow Tracts.. Circulation. Cardiovascular interventions. 2025. DOI: 10.1161/circinterventions.125.015325.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.