MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circinterventions.116.003920

Медицинская библиотека · Circulation. Cardiovascular interventions · 2016

Implantation of the Medtronic Harmony Transcatheter Pulmonary Valve Improves Right Ventricular Size and Function in an Ovine Model of Postoperative Chronic Pulmonary Insufficiency.

Schoonbeek Rosanne C, Takebayashi Satoshi, Aoki Chikashi, Shimaoka Toru, Harris Matthew A, Fu Gregory L, Kim Timothy S, Dori Yoav, McGarvey Jeremy, Litt Harold, Bouma Wobbe, Zsido Gerald, Glatz Andrew C, Rome Jonathan J, Gorman Robert C, Gorman Joseph H, Gillespie Matthew J

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Pulmonary insufficiency is the nexus of late morbidity and mortality after transannular patch repair of tetralogy of Fallot. This study aimed to establish the feasibility of implantation of the novel Medtronic Harmony transcatheter pulmonary valve (hTPV) and to assess its effect on pulmonary insufficiency and ventricular function in an ovine model of chronic postoperative pulmonary insufficiency.

METHODS AND

RESULTS

Thirteen sheep underwent baseline cardiac magnetic resonance imaging, surgical pulmonary valvectomy, and transannular patch repair. One month after transannular patch repair, the hTPV was implanted, followed by serial magnetic resonance imaging and computed tomography imaging at 1, 5, and 8 month(s). hTPV implantation was successful in 11 animals (85%). There were 2 procedural deaths related to ventricular fibrillation. Seven animals survived the entire follow-up protocol, 5 with functioning hTPV devices. Two animals had occlusion of hTPV with aneurysm of main pulmonary artery. A strong decline in pulmonary regurgitant fraction was observed after hTPV implantation (40.5% versus 8.3%; P=0.011). Right ventricular end diastolic volume increased by 49.4% after transannular patch repair (62.3-93.1 mL/m2; P=0.028) but was reversed to baseline values after hTPV implantation (to 65.1 mL/m2 at 8 months, P=0.045). Both right ventricular ejection fraction and left ventricular ejection fraction were preserved after hTPV implantation.

CONCLUSIONS

hTPV implantation is feasible, significantly reduces pulmonary regurgitant fraction, facilitates right ventricular volume improvements, and preserves biventricular function in an ovine model of chronic pulmonary insufficiency. This percutaneous strategy could potentially offer an alternative for standard surgical pulmonary valve replacement in dilated right ventricular outflow tracts, permitting lower risk, nonsurgical pulmonary valve replacement in previously prohibitive anatomies.

Для цитирования: Schoonbeek Rosanne C, Takebayashi Satoshi, Aoki Chikashi, Shimaoka Toru, Harris Matthew A, Fu Gregory L, Kim Timothy S, Dori Yoav, McGarvey Jeremy, Litt Harold, Bouma Wobbe, Zsido Gerald, Glatz Andrew C, Rome Jonathan J, Gorman Robert C, Gorman Joseph H, Gillespie Matthew J. Implantation of the Medtronic Harmony Transcatheter Pulmonary Valve Improves Right Ventricular Size and Function in an Ovine Model of Postoperative Chronic Pulmonary Insufficiency.. Circulation. Cardiovascular interventions. 2016. DOI: 10.1161/circinterventions.116.003920.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.