MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1126/scitranslmed.adk2936

Медицинская библиотека · Science translational medicine · 2024

Hemodynamic evaluation of biomaterial-based surgery for Tetralogy of Fallot using a biorobotic heart, in silico, and ovine models.

Singh Manisha, Roubertie François, Ozturk Caglar, Borchiellini Paul, Rames Adeline, Bonnemain Jean, Gollob Samuel Dutra, Wang Sophie X, Naulin Jérôme, El Hamrani Dounia, Dugot-Senant Nathalie, Gosselin Isalyne, Grenet Célia, L'Heureux Nicolas, Roche Ellen T, Kawecki Fabien

СтатьяПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаПоддержка правительства СШАПеревод в очереди

Аннотация

Tetralogy of Fallot is a congenital heart disease affecting newborns and involves stenosis of the right ventricular outflow tract (RVOT). Surgical correction often widens the RVOT with a transannular enlargement patch, but this causes issues including pulmonary valve insufficiency and progressive right ventricle failure. A monocusp valve can prevent pulmonary regurgitation; however, valve failure resulting from factors including leaflet design, morphology, and immune response can occur, ultimately resulting in pulmonary insufficiency. A multimodal platform to quantitatively evaluate the effect of shape, size, and material on clinical outcomes could optimize monocusp design. This study introduces a benchtop soft biorobotic heart model, a computational fluid model of the RVOT, and a monocusp valve made from an entirely biological cell-assembled extracellular matrix (CAM) to tackle the multifaceted issue of monocusp failure. The hydrodynamic and mechanical performance of RVOT repair strategies was assessed in biorobotic and computational platforms. The monocusp valve design was validated in vivo in ovine models through echocardiography, cardiac magnetic resonance, and catheterization. These models supported assessment of surgical feasibility, handling, suturability, and hemodynamic and mechanical monocusp capabilities. The CAM-based monocusp offered a competent pulmonary valve with regurgitation of 4.6 ± 0.9% and a transvalvular pressure gradient of 4.3 ± 1.4 millimeters of mercury after 7 days of implantation in sheep. The biorobotic heart model, in silico analysis, and in vivo RVOT modeling allowed iteration in monocusp design not now feasible in a clinical environment and will support future surgical testing of biomaterials for complex congenital heart malformations.

Для цитирования: Singh Manisha, Roubertie François, Ozturk Caglar, Borchiellini Paul, Rames Adeline, Bonnemain Jean, Gollob Samuel Dutra, Wang Sophie X, Naulin Jérôme, El Hamrani Dounia, Dugot-Senant Nathalie, Gosselin Isalyne, Grenet Célia, L'Heureux Nicolas, Roche Ellen T, Kawecki Fabien. Hemodynamic evaluation of biomaterial-based surgery for Tetralogy of Fallot using a biorobotic heart, in silico, and ovine models.. Science translational medicine. 2024. DOI: 10.1126/scitranslmed.adk2936.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.