Type A aortic dissection during transoesophageal echocardiography: a case report.

Lee Chung-Yen, Chiang Kuang-Chien, Lee Wen-Jeng, Chan Chih-Yang, Yang Li-Tan

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

The occurrence of type A aortic dissection (TAAD) during transoesophageal echocardiography (TEE) has only been reported once. We present another case of pre-procedural type B AD with retrograde TAAD or de novo TAAD during the TEE procedure.

CASE SUMMARY: An 81-year-old man with a pre-existing infrarenal abdominal aortic aneurysm and highly tortuous aorta was referred to our ward for acute decompensated heart failure (ADHF) with New York Heart Association functional class II. On hospital Day 2, the patient complained of intermittent dull pain over chest and back; ADHF or acute coronary syndrome was suspected. On Day 3, we transferred the patient to the intensive care unit due to ADHF with cardiogenic shock attributed to fluid overload, atrial fibrillation with rapid ventricular response, and severe mitral regurgitation with severely impaired left ventricular ejection fraction. Given the heightened surgical risk, TEE was performed to evaluate the eligibility of mitral transcatheter edge-to-edge repair. The first mid-oesophageal long-axis view showed no evidence of dissection. After 20 min, the same view showed the occurrence of TAAD. Urgent contrast CT confirmed a TAAD extending from the aortic root to the infrarenal abdominal aorta. Due to the prohibitive risk for surgical repair of TAAD, the patient received palliative care and unfortunately passed away on hospital Day 6.

DISCUSSION: Albeit rare, TAAD could progress or de novo occur during TEE, especially in high-risk patients. Therefore, high alertness during TEE procedures is imperative. Moreover, in patients with AD and poor renal function, the risk of using TEE as an alternative diagnostic modality should be carefully considered.

Для цитирования: Lee Chung-Yen, Chiang Kuang-Chien, Lee Wen-Jeng, Chan Chih-Yang, Yang Li-Tan. Type A aortic dissection during transoesophageal echocardiography: a case report.. European heart journal. Case reports. 2024. DOI: 10.1093/ehjcr/ytae413.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.