MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s41747-023-00379-0

Медицинская библиотека · European radiology experimental · 2023

Diagnostic performance of short noncontrast biparametric 3-T MRI for tonsillar infections: comparison with a full protocol including contrast-enhanced sequences.

Vierula Jari-Pekka, Nurminen Janne, Jussila Ville, Nyman Mikko, Heikkinen Jaakko, Pape Bernd, Sorvettula Kaarlo, Mattila Kimmo, Hirvonen Jussi

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

We investigated whether a short, 5-min magnetic resonance imaging (MRI) protocol consisting of only axial T2-weighted and diffusion-weighted imaging (DWI) sequences can discriminate between tonsillar infections, peritonsillar abscesses and deeply extending abscesses in a retrospective, blinded, multireader setting.

METHODS

We included patients sent by emergency physicians with suspected pharyngotonsillar infections who underwent emergency neck 3-T MRI from April 1 2013 to December 31 2018. Three radiologists (with 10-16 years of experience) reviewed the images for abscesses and their extension into deep neck spaces. Data were reviewed first using only axial T2-weighted Dixon images and DWI (short protocol) and second including other sequences and contrast-enhanced T1-weighted Dixon images (full protocol). Diagnostic accuracy, interobserver agreement, and reader confidence were measured. Surgical findings and clinical course served as standard of reference.

RESULTS

The final sample consisted of 52 patients: 13 acute tonsillitis with no abscesses, 19 peritonsillar abscesses, and 20 deeply extending abscesses. Using the short protocol, diagnostic accuracy for abscesses across all readers was good-to-excellent: sensitivity 0.93 (95% confidence interval 0.87-0.97), specificity 0.85 (0.70-0.93), accuracy 0.91 (0.85-0.95). Using the full protocol, respective values were 0.98 (0.93-1.00), 0.85 (0.70-0.93), and 0.95 (0.90-0.97), not significantly different compared with the short protocol. Similar trends were seen with detecting deep extension. Interobserver agreement was similar between protocols. However, readers had higher confidence in diagnosing abscesses using the full protocol.

CONCLUSIONS

Short MRI protocol showed good-to-excellent accuracy for tonsillar abscesses. Contrast-enhanced images improved reader confidence but did not affect diagnostic accuracy or interobserver agreement.

RELEVANCE STATEMENT: Short protocol consisting only of T2-weighted Dixon and DWI sequences can accurately image tonsillar abscesses, which may improve feasibility of emergency neck MRI.

KEY POINTS: • The short 3-T MRI protocol (T2-weighted images and DWI) was faster (5 min) than the full protocol including T1-weighted contrast-enhanced images (24 min). • The short 3-T MRI protocol showed good diagnostic accuracy for pharyngotonsillar abscesses. • Contrast-enhanced sequences improved reader confidence but did not impact diagnostic accuracy or interobserver agreement.

Для цитирования: Vierula Jari-Pekka, Nurminen Janne, Jussila Ville, Nyman Mikko, Heikkinen Jaakko, Pape Bernd, Sorvettula Kaarlo, Mattila Kimmo, Hirvonen Jussi. Diagnostic performance of short noncontrast biparametric 3-T MRI for tonsillar infections: comparison with a full protocol including contrast-enhanced sequences.. European radiology experimental. 2023. DOI: 10.1186/s41747-023-00379-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.