BMC ophthalmology · 2022
Comparison of different pupil dilatation methods for phacoemulsification in eyes with a small pupil.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Wang Jin Da, Zhang Jing Shang, Li Meng, Mao Ying Yan, Mayinuer Yusufu, Wan Xiu Hua
Аннотация
PURPOSE: To compare 6 methods for intraoperative pupil dilatation in eyes with insufficient pupil size during phacoemulsification.
METHODS: This was a prospective case-control study. 99 microcoria cataract patients (120 eyes) were collected and were divided into 6 groups(20 eyes each group), and their pupils were dilated by bimanual stretching pupil (group I), pupil radial cut open(group II), mechanical pupil dilatation with iris-retractor hooks (group III), OASIS iris expander (group IV), and Malyguin-ring (Microsurgical company, America) (group V), B-HEX Pupil Expander (Med Invent Devics, India)(group VI),respectively. 3.0 mm clear corneal incision were used in phacoemulsification. All cases were followed up at 1 week and 1, 3, 6 months after the surgery. The best corrected visual acuity (BCVA), intraocular pressure(IOP), corneal endothelium cell density(ECD), pupil diameter(PD) of before and after surgery were compared.
RESULTS: One same doctor finished all cataract surgeries successfully. The eyes' condition before surgery and at 6 months after surgery were compared. There were no significant statistical differences for the conditions of the eyes before surgery among six groups. The ECDs were better at 6 months postoperatively in group III and V, median values: 2114/mm2, 1961/mm2. PD was largest in group II (median value: 5.5 mm), which was significantly larger than other groups (Padjusted < 0.05).
CONCLUSIONS: All 6 methods used in this study were effective for the mechanical dilatation of small pupils and didn't affect the postoperative visual acuity and intraocular pressure in microcoria cataract phacoemulsification. Iris-retractor hooks and the Malyugin Ring can reduce intraoperative corneal endothelium cell loss. Postoperative PD is larger when the iris was cut open radially.
METHODS: This was a prospective case-control study. 99 microcoria cataract patients (120 eyes) were collected and were divided into 6 groups(20 eyes each group), and their pupils were dilated by bimanual stretching pupil (group I), pupil radial cut open(group II), mechanical pupil dilatation with iris-retractor hooks (group III), OASIS iris expander (group IV), and Malyguin-ring (Microsurgical company, America) (group V), B-HEX Pupil Expander (Med Invent Devics, India)(group VI),respectively. 3.0 mm clear corneal incision were used in phacoemulsification. All cases were followed up at 1 week and 1, 3, 6 months after the surgery. The best corrected visual acuity (BCVA), intraocular pressure(IOP), corneal endothelium cell density(ECD), pupil diameter(PD) of before and after surgery were compared.
RESULTS: One same doctor finished all cataract surgeries successfully. The eyes' condition before surgery and at 6 months after surgery were compared. There were no significant statistical differences for the conditions of the eyes before surgery among six groups. The ECDs were better at 6 months postoperatively in group III and V, median values: 2114/mm2, 1961/mm2. PD was largest in group II (median value: 5.5 mm), which was significantly larger than other groups (Padjusted < 0.05).
CONCLUSIONS: All 6 methods used in this study were effective for the mechanical dilatation of small pupils and didn't affect the postoperative visual acuity and intraocular pressure in microcoria cataract phacoemulsification. Iris-retractor hooks and the Malyugin Ring can reduce intraoperative corneal endothelium cell loss. Postoperative PD is larger when the iris was cut open radially.