MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajic.2026.09.005

Медицинская библиотека · American journal of infection control · 2026

Effectiveness of UV-C disinfection on bacterial contamination of lead aprons in radiology departments.

Li Jing, Hu Xuanzi, Hu Song, Gou Mingdong, Ren Liangxuan, Jia Haoyang, Chen Tingyu

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Lead protective aprons are widely used by health care workers and patients during radiological examinations and interventional procedures to reduce radiation exposure. However, inadequate cleaning and disinfection may result in bacterial contamination, posing a potential risk of health care-associated infections. This study aimed to evaluate the efficacy of an automated ultraviolet-C (UV-C) disinfection cabinet in reducing bacterial contamination on lead protective aprons used in computed tomography (CT) examination rooms, interventional procedure suites, and intensive care unit (ICU) bedside imaging environments.

METHODS

A total of 12 lead aprons that had been in frequent clinical use for more than 6 months without cleaning were collected. The aprons were sourced from CT examination rooms, interventional procedure rooms, and ICU bedside imaging areas. Bacterial cultures were obtained from all aprons both before and after exposure to UV-C disinfection.

RESULTS

Before disinfection, bacterial contamination was detected at all sampling sites. The thyroid shield had the highest median colony count [12.0 (IQR, 8.8-16.0) CFU], followed by the lead protective cap [9.5 (IQR, 8.3-14.3) CFU], lead apron [6.5 (IQR, 3.8-8.0) CFU], and lead skirt [5.5 (IQR, 2.3-7.3) CFU]. Following UV-C disinfection, the median bacterial colony count at all sampling sites was reduced to 0 CFU. Mean reductions ranged from 4.92 to 11.17 CFU, corresponding to reduction rates of 98.3-100.0%. Wilcoxon signed-rank tests showed statistically significant decreases in colony counts at all sampling sites (all P ≤ .004). Overall, UV-C disinfection achieved a 99.49% reduction in bacterial contamination.

CONCLUSIONS

These findings indicate that the automated UV-C disinfection cabinet significantly reduces bacterial contamination on lead aprons, thereby strengthening infection control measures and improving safety for both patients and health care personnel in radiological care environments.

Для цитирования: Li Jing, Hu Xuanzi, Hu Song, Gou Mingdong, Ren Liangxuan, Jia Haoyang, Chen Tingyu. Effectiveness of UV-C disinfection on bacterial contamination of lead aprons in radiology departments.. American journal of infection control. 2026. DOI: 10.1016/j.ajic.2026.09.005.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.