Surgical removal of orbital tumors by orbital approach using ultrasonic surgical system SONOPET®.
Аннотация
PURPOSE: Orbital tumor surgery can be challenging when the tumor is located in a very narrow surgical field and close to important structures, such as nerves or extraocular muscles that can be damaged during surgery. Advances in technology and special surgical techniques help to avoid such damage. We describe our experience using SONOPET® ultrasonic surgical aspirator to remove 12 different orbital tumors that were difficult to treat due to their poorly defined borders, adhesions, or location.
METHODS
This is a retrospective case series that describes 12 operations that occurred between March 2016 to December 2018 using an ultrasonic device to debulk or remove orbital tumors. Different approaches and handpieces were used for each case depending on the location and consistency of the tumor.
RESULTS
All patients experienced an improvement in preoperative signs and symptoms, pain, proptosis, diplopia, or lagophthalmos. Visual acuity, which had been reduced due to the tumor, was also recovered. There were no intraoperative or postoperative complications due to the use of the device.
CONCLUSIONS
The ultrasonic aspirator is a safe, useful device that can successfully remove or debulk infiltrating orbital masses through any orbital access, regardless of their consistency. It is helpful in cases of difficult anatomical access or difficult extraction due to size or adhesions to the surrounding tissues.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.