BACKGROUND

Hepatorenal dysfunction is a strong prognostic predictor in patients with heart failure. However, the prognostic impact of the hepatorenal dysfunction in patients undergoing transcatheter mitral valve repair (TMVR) has not been well studied.

METHODS

In consecutive patients who underwent edge-to-edge TMVR at three German centers, the model for end-stage liver disease excluding international normalized ratio (MELD-XI) score was calculated as 5.11 × ln [serum total bilirubin (mg/dl)] + 11.76 × ln [serum creatinine (mg/dl)] + 9.44. Patients were stratified into high (> 11) or low (≤ 11) MELD-XI score of which an incidence of the composite outcome, consisting of all-cause mortality and heart failure hospitalization, within 2 years after TMVR was assessed.

RESULTS

Of the 881 patients, the mean MELD-XI score was 11.0 ± 5.9, and 415 patients (47.1%) had high MELD-XI score. The MELD-XI score was correlated with male, effective regurgitant orifice area, and tricuspid regurgitation severity and inversely related to left ventricular ejection fraction. Patients with high MELD-XI score had a higher incidence of the composite outcome than those with low MELD-XI score (47.7% vs. 29.8%; p < 0.0001), and in multivariable analysis, the high MELD-XI score was an independent predictor of the composite outcome [adjusted hazard ratio (HR) 1.34; 95% confidence interval (CI) 1.02-1.77; p = 0.04). Additionally, the MELD-XI score as a continuous variable was also an independent predictor (adjusted HR 1.02; 95% CI 1.00-1.05; p = 0.048).

CONCLUSIONS

The MELD-XI score was associated with clinical outcomes within 2 years after TMVR and can be a useful risk-stratification tool in patients undergoing TMVR.

Для цитирования: Tanaka Tetsu, Kavsur Refik, Spieker Maximilian, Iliadis Christos, Metze Clemens, Horn Patrick, Sugiura Atsushi, Baldus Stephan, Kelm Malte, Nickenig Georg, Pfister Roman, Westenfeld Ralf, Becher Marc Ulrich. Prognostic value of hepatorenal function following transcatheter edge-to-edge mitral valve repair.. Clinical research in cardiology : official journal of the German Cardiac Society. 2021. DOI: 10.1007/s00392-021-01908-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.