Redo partial aortic root remodelling in type A dissection with an aorto-left atrial fistula.

Ohira Suguru, Gregory Vasiliki, Spielvogel David

Клинический случайVideo-Audio MediaСтатьяПеревод в очереди

Аннотация

A 72-year-old male with a history of a triple-vessel coronary artery bypass graft years ago presented with a DeBakey type 2 aortic dissection and an aorto-left atrial fistula with patent bypass grafts (left internal mammary artery and saphenous vein grafts). He developed pulmonary oedema and required intubation. The right axillary artery was cannulated. After the ascending aorta and left internal mammary artery were clamped, the aorta was transected, leaving aortic tissue around two saphenous vein grafts as two separate patches. An entry tear was found adjacent to the proximal anastomosis of the saphenous vein graft to the posterior descending artery. A fistula, which was located between a false lumen in the non-coronary sinus and the dome of the left atrium, was primarily closed. Because the adventitia was thinned out in the non-coronary sinus due to aortic dissection, partial aortic root remodelling was performed with resuspension of the commissures. Hemiarch repair was performed under moderate hypothermia and unilateral antegrade cerebral perfusion. After systemic perfusion was resumed, the locations of the saphenous vein graft buttons were determined. The ascending graft was cross-clamped again; the saphenous vein graft to the obtuse marginal branch graft was reimplanted using the Carrel patch technique while a saphenous vein graft to the posterior descending artery required interposition of a 10-mm Dacron graft to accommodate the length.

Для цитирования: Ohira Suguru, Gregory Vasiliki, Spielvogel David. Redo partial aortic root remodelling in type A dissection with an aorto-left atrial fistula.. Multimedia manual of cardiothoracic surgery : MMCTS. 2024. DOI: 10.1510/mmcts.2024.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.