Impact of a structured quantitative program on [18F]FP-CIT PET interpretation: a multicenter study of diagnostic accuracy, interrater reliability, and reader confidence.

Choi Byungwook, Ha Seunggyun, Kang Sungmin, Kwon Soo Jin, Son Junik, Jeong Shin Young, Lee Sang-Woo, Choe Yeong Sim, Kim Donghyeon, Hong Chae Moon

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

OBJECTIVES

This study assessed the impact of a structured quantitative analysis program on diagnostic performance, interrater reliability, and reader confidence in interpreting N-3-[18F]fluoropropyl-2β-carbomethoxy-3β-4-iodophenyl nortropane positron emission tomography ([18F]FP-CIT PET) scans to differentiate idiopathic Parkinson's disease from essential tremor-/drug-induced parkinsonism.

METHODS

This retrospective multicenter study included 637 patients who underwent [18F]FP-CIT PET and brain magnetic resonance imaging scans for evaluation of Parkinsonian syndromes at 4 institutions between January 2015 and October 2022. Readers evaluated the scans qualitatively in the pre-program session and with access to quantitative parameters in the post-program session, with a 1-month minimum interval to minimize recall bias. Diagnostic performance metrics (sensitivity, specificity, accuracy), interrater reliability (Cohen's κ), and reader confidence (low/moderate vs high) were compared.

RESULTS

Following program implementation, interrater reliability significantly improved from substantial to almost perfect (Cohen's κ: 0.768-0.970; P < .001), and a significant shift toward high-confidence ratings was observed (P < .001). Diagnostic accuracy also significantly improved from 92.8% to 94.3% (P = .036). Although the increase in the area under the curve (0.922-0.932) did not reach statistical significance (P = .163), likely due to a ceiling effect, reader performance significantly surpassed that of the quantitative parameter alone only after program implementation, whereas it was comparable at baseline.

CONCLUSIONS

These findings suggest that integrating quantitative analysis tools may improve diagnostic consistency and reliability in clinical practice.

ADVANCES IN KNOWLEDGE: The structured quantitative analysis program significantly improved [18F]FP-CIT PET/CT interpretation by increasing diagnostic accuracy, interrater reliability, and reader confidence.

Для цитирования: Choi Byungwook, Ha Seunggyun, Kang Sungmin, Kwon Soo Jin, Son Junik, Jeong Shin Young, Lee Sang-Woo, Choe Yeong Sim, Kim Donghyeon, Hong Chae Moon. Impact of a structured quantitative program on [18F]FP-CIT PET interpretation: a multicenter study of diagnostic accuracy, interrater reliability, and reader confidence.. The British journal of radiology. 2026. DOI: 10.1093/bjr/tqag045.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.