MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.echo.2021.04.017

Медицинская библиотека · Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography · 2021

Reference Ranges for Pulsed-Wave Doppler of the Fetal Cardiac Inflow and Outflow Tracts from 13 to 36 Weeks' Gestation.

Zidere Vita, Vigneswaran Trisha V, Syngelaki Argyro, Charakida Marietta, Allan Lindsey D, Nicolaides Kypros H, Simpson John M, Akolekar Ranjit

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Doppler assessment of ventricular filling and outflow tract velocities is an integral part of fetal echocardiography, to assess diastolic function, systolic function, and outflow tract obstruction. There is a paucity of prospective data from a large sample of normal fetuses in the published literature. The authors report reference ranges for pulsed-wave Doppler flow of the mitral valve, tricuspid valve, aortic valve, and pulmonary valve, as well as heart rate, in a large number of fetuses prospectively examined at a single tertiary fetal cardiology center.

METHODS

The study population comprised 7,885 fetuses at 13 to 36 weeks' gestation with no detectable abnormalities from pregnancies resulting in normal live births. Prospective pulsed-wave Doppler blood flow measurements were taken of the mitral, tricuspid, aortic, and pulmonary valves. The fetal heart rate was recorded at the time of each assessment. Regression analysis, with polynomial terms to assess for linear and nonlinear contributors, was used to establish the relationship between each measurement and gestational age.

RESULTS

The measurement for each cardiac Doppler measurement was expressed as a Z score (difference between observed and expected values divided by the fitted SD corrected for gestational age) and percentile. Analysis included calculation of gestation-specific SDs. Regression equations are provided for the cardiac inflow and outflow tracts.

CONCLUSIONS

This study establishes reference ranges for fetal cardiac Doppler measurements and heart rate between 13 to 36 weeks' gestation that may be useful in clinical practice.

Для цитирования: Zidere Vita, Vigneswaran Trisha V, Syngelaki Argyro, Charakida Marietta, Allan Lindsey D, Nicolaides Kypros H, Simpson John M, Akolekar Ranjit. Reference Ranges for Pulsed-Wave Doppler of the Fetal Cardiac Inflow and Outflow Tracts from 13 to 36 Weeks' Gestation.. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. 2021. DOI: 10.1016/j.echo.2021.04.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.