MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10840-018-0389-0

Медицинская библиотека · Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2018

Association of cardiac implantable electronic devices with survival in bifascicular block and prolonged PR interval on electrocardiogram.

Moulki Naeem, Kealhofer Jessica V, Benditt David G, Gravely Amy, Vakil Kairav, Garcia Santiago, Adabag Selcuk

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: Bifascicular block and prolonged PR interval on the electrocardiogram (ECG) have been associated with complete heart block and sudden cardiac death. We sought to determine if cardiac implantable electronic devices (CIED) improve survival in these patients.

METHODS

We assessed survival in relation to CIED status among 636 consecutive patients with bifascicular block and prolonged PR interval on the ECG. In survival analyses, CIED was considered as a time-varying covariate.

RESULTS

Average age was 76 ± 9 years, and 99% of the patients were men. A total of 167 (26%) underwent CIED (127 pacemaker only) implantation at baseline (n = 23) or during follow-up (n = 144). During 5.4 ± 3.8 years of follow-up, 83 (13%) patients developed complete or high-degree atrioventricular block and 375 (59%) died. Patients with a CIED had a longer survival compared to those without a CIED in the traditional, static analysis (log-rank p < 0.0001) but not when CIED was considered as a time-varying covariate (log-rank p = 0.76). In the multivariable model, patients with a CIED had a 34% lower risk of death (hazard ratio 0.66, 95% confidence interval 0.52-0.83; p = 0.001) than those without CIED in the traditional analysis but not in the time-varying covariate analysis (hazard ratio 1.05, 95% confidence interval 0.79-1.38; p = 0.76). Results did not change in the subgroup with a pacemaker only.

CONCLUSIONS

Bifascicular block and prolonged PR interval on ECG are associated with a high incidence of complete atrioventricular block and mortality. However, CIED implantation does not have a significant influence on survival when time-varying nature of CIED implantation is considered.

Для цитирования: Moulki Naeem, Kealhofer Jessica V, Benditt David G, Gravely Amy, Vakil Kairav, Garcia Santiago, Adabag Selcuk. Association of cardiac implantable electronic devices with survival in bifascicular block and prolonged PR interval on electrocardiogram.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2018. DOI: 10.1007/s10840-018-0389-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.