MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/wno.0000000000000060

Медицинская библиотека · Journal of neuro-ophthalmology : the official journal of the North American Neuro-Ophthalmology Society · 2014

Patients with homonymous hemianopia become visually qualified to drive using novel monocular sector prisms.

Moss Adam M, Harrison Andrew R, Lee Michael S

Клинический случайСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Patients with homonymous hemianopia (HH) often fail to meet visual field (VF) requirements for a driver's license. We describe 2 patients with complete HH, who met the minimum VF requirements for driving using a novel, high-power, monocular sector prism system. Baseline VFs were assessed using automated and kinetic perimetry. Patients were fitted with glasses and press-on 57-PD peripheral monocular sector prisms placed on the lens ipsilateral to the VF defect above and below the visual axis with prisms oriented obliquely. Kinetic perimetry was reassessed both monocularly and binocularly, with and without prisms. The 2 patients had 95° and 82° angle of continuous, horizontal, binocular VF. With the use of the prism system, the binocular VF increased to 115° and 112° angles. Both patients reported improvement in quality of life and each holds a valid driver's license and has successfully operated a motor vehicle without any restrictions or accidents. These findings suggest that the addition of oblique 57-PD prisms to the ipsilateral spectacle lens above and below the visual axis for patients with complete HH can significantly increase horizontal VF, which may help an individual become visually qualified to obtain a driver's license.

Для цитирования: Moss Adam M, Harrison Andrew R, Lee Michael S. Patients with homonymous hemianopia become visually qualified to drive using novel monocular sector prisms.. Journal of neuro-ophthalmology : the official journal of the North American Neuro-Ophthalmology Society. 2014. DOI: 10.1097/wno.0000000000000060.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.