MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.compbiomed.2021.104612

Медицинская библиотека · Computers in biology and medicine · 2021

Influence of the eye globe design on biomechanical analysis.

Issarti Ikram, Koppen Carina, Rozema Jos J

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To assess the mechanical contribution of inner eye components on corneal deformation during a finite element analysis.

METHODS

A finite element model of an eye globe was implemented to examine the corneal response under various mechanical conditions. The model incorporates the cornea, limbus, sclera, iris, lens, muscles, anterior chamber and vitreous. The Ogden hyperelastic model was used for the corneo-limbal region and the Yeoh isotropic model for the sclera. The anterior chamber was modelled as a cavity and other eye components were incorporated as linear elastic material. A fluid dynamic simulation was implemented to determine the spatial air puff velocity and pressure profiles around corneal surface.

RESULTS

The maximal apical displacement under IOP = 15 mmHg was 0.22 mm with a stress of 0.013 MPa. An unrestrained limbus slightly increases the apical displacement, while an unrestrained equatorial sclera largely increases the displacement by 10%, resulting in reduced stiffness. The iris slightly decreases the displacement but increases stress in the corneal periphery. Meanwhile, the joint contribution of muscle and lens cannot be neglected as it reduces corneal displacement by 50%. Incorporation of the remaining eye components results in nearly similar results. Under air puff loading, a free equatorial sclera raised the dynamic deformation amplitude by nearly 2%, while the dynamic profile remained similar for all remaining study cases considered.

CONCLUSION

In a finite element analysis, the lens, iris, and muscle each provide major mechanical contributions to corneal deformation, and it is highly recommended that the internal contributions are considered.

Для цитирования: Issarti Ikram, Koppen Carina, Rozema Jos J. Influence of the eye globe design on biomechanical analysis.. Computers in biology and medicine. 2021. DOI: 10.1016/j.compbiomed.2021.104612.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.