MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.yrtph.2021.105098

Медицинская библиотека · Regulatory toxicology and pharmacology : RTP · 2021

Use of alternative test methods in a tiered testing approach to address photoirritation potential of fragrance materials.

Ritacco Gretchen, Hilberer Allison, Lavelle Maura, Api Anne Marie

СтатьяПеревод в очереди

Аннотация

The safety assessment of fragrance materials for photoirritation utilized by The Research Institute for Fragrance Materials has recently been modified and is described in detail. Materials demonstrating significant absorbance in the ultraviolet and visible light (UV/VIS) range (290-700 nm) may present a concern for photoirritation and require further investigation. If there are no photoirritation data or data are insufficient, then data on read-across materials are considered before a tiered approach for testing begins. The hazard-based 3T3-Neutral Red Uptake (NRU) Phototoxicity Test (OECD TG 432) is used as a first-tier assay; if it predicts photoirritation, it is followed by the reconstructed human epidermis (RhE) phototoxicity assay (OECD TG 498). The RhE phototoxicity assay is used to determine a No Observed Effect Level (NOEL) for photoirritation that is used in a confirmatory human photoirritation test. Data are presented on 108 fragrance materials exhibiting significant UV/VIS absorbance and evaluated in the 3T3-NRU Phototoxicity Assay. Twenty-one materials were predicted to be phototoxic; twenty were evaluated in the RhE Phototoxicity Assay to establish a NOEL. Fourteen materials were then evaluated in a confirmatory human phototoxicity test. The tiered testing approach presented represents a scientifically pragmatic method to minimize the likelihood of photoirritation from fragrance materials.

Для цитирования: Ritacco Gretchen, Hilberer Allison, Lavelle Maura, Api Anne Marie. Use of alternative test methods in a tiered testing approach to address photoirritation potential of fragrance materials.. Regulatory toxicology and pharmacology : RTP. 2021. DOI: 10.1016/j.yrtph.2021.105098.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.