A comparative study of porous polyethylene versus absorbable polydextro- and polylevolactic-lactide plate in reconstruction of isolated medial orbital wall fracture.

Cha Han Gyu, Nam Seung Min, Kim Yong Bae, Park Eun Soo, Choi Chang Yong

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Several materials for medial orbital wall reconstruction have been mentioned in the literature. Our main purpose was to investigate postoperative enophthalmos and diplopia after medial orbital wall reconstruction with polydextro- and polylevolactic (poly-L/DL) acid (P[L/DL]LA) mesh plates and porous polyethylene plates.

METHODS

Using a retrospective study design, we enrolled a cohort of isolated medial blowout fracture patients treated during a 58-month interval. The predictor variable was medial orbital wall reconstruction materials (P(L/DL)LA mesh plate and porous polyethylene plate. The main outcome variables included the occurrence of postoperative enophthalmos and diplopia at 1 week, 1, 3, 6, and 12 months post-surgery. Appropriate descriptive, uni- and bivariate statistics were computed, and P < 0.05 was considered significant.

RESULTS

Three hundred-two isolated medial blowout fracture patients were included (24.5% females, 67% treated with P(L/DL)LA mesh plate). Exophthalmos measured highest in both groups 1 week after surgery and decreased steadily for 6 months postoperatively. Statistically significant differences were observed between both groups at 1 week, 1 month, and 3 months after surgery, with a higher incidence of exophthalmos observed in the P(L/DL)LA mesh plate group (P < 0.001). No significant differences were observed at 6 and 12 months after surgery.

CONCLUSION

The occurrence of enophthalmos after medial blowout fracture reconstruction with P(L/DL)LA mesh plate is comparable with the use of porous polyethylene plate. Both P(L/DL)LA mesh and porous polyethylene plates are, therefore, reliable implants for medial orbital wall reconstruction.

Для цитирования: Cha Han Gyu, Nam Seung Min, Kim Yong Bae, Park Eun Soo, Choi Chang Yong. A comparative study of porous polyethylene versus absorbable polydextro- and polylevolactic-lactide plate in reconstruction of isolated medial orbital wall fracture.. Journal of plastic, reconstructive & aesthetic surgery : JPRAS. 2021. DOI: 10.1016/j.bjps.2021.08.023.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.