Conduction Disturbances and Permanent Pacemaker Implantation After TAVR With Self-Expanding Devices: The CONNAVIPRO Study.

Poletti Enrico, Oliva Omar Alessandro, Hassan Ahmad, Esposito Giuseppe, Massussi Mauro, Ardizzone Valentina, Nurcan Baydaroglu, Millin Antonella, Zuccarelli Vittorio, Munafò Andrea Raffaele, Oreglia Jacopo, De Marco Federico, Adamo Marianna, Tchetché Didier, Zuffi Andrea

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The Evolut and the Navitor transcatheter heart valves (THVs) represent the most widely used self-expanding implanted valves. Despite a similar implant concept, they markedly differ in design and hemodynamic performance. In both THVs, conduction disturbances following transcatheter aortic valve replacement (TAVR) are reported higher than in balloon-expandable devices. Nevertheless, to date, no direct comparative studies have analyzed their real difference rates.

AIM: Aim of the present study was to directly compare the self-expanding Evolut PRO+ and Navitor THVs, with specific focus on the incidence of new permanent pacemaker implantation (PPI) and post-procedural hemodynamic performance.

METHODS

The CONNAVIPRO registry is an international, multicenter, retrospective study including 880 consecutive patients with severe aortic stenosis treated with Evolut PRO+ (n = 451) or Navitor (n = 429) between May 2022 and December 2024. The primary endpoint was new PPI within 30 days among pacemaker-naïve patients. Secondary endpoints included technical and device success, transprosthetic gradients, and paravalvular leak (PVL). Inverse probability weighting (IPW) was applied to adjust for baseline differences.

RESULTS

Procedural success was high with both valves (97.6%), and early safety outcomes were comparable. At 30 days, the Navitor group showed a higher PPI rate than Evolut (23.2% vs. 17.6%), reaching statistical significance after IPW adjustment (OR 1.53, 95% CI 1.08-2.17; p = 0.018). Mean transprosthetic gradients were slightly higher with Navitor (8 vs. 7 mmHg; p = 0.002), whereas moderate or greater PVL was less frequent (2.8% vs. 7.7%; p < 0.001). Variables independently associated with PPI were hypertension, and pre-existing right bundle branch block.

CONCLUSIONS

Both Evolut PRO+ and Navitor THVs provided excellent safety and hemodynamic outcomes. Navitor may be associated with a higher 30-day PPI rate, a lower incidence of moderate or greater PVL, and clinically non-significant higher gradients. These associations should be interpreted as hypothesis-generating and warrant confirmation in prospective studies.

Для цитирования: Poletti Enrico, Oliva Omar Alessandro, Hassan Ahmad, Esposito Giuseppe, Massussi Mauro, Ardizzone Valentina, Nurcan Baydaroglu, Millin Antonella, Zuccarelli Vittorio, Munafò Andrea Raffaele, Oreglia Jacopo, De Marco Federico, Adamo Marianna, Tchetché Didier, Zuffi Andrea. Conduction Disturbances and Permanent Pacemaker Implantation After TAVR With Self-Expanding Devices: The CONNAVIPRO Study.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2026. DOI: 10.1002/ccd.70827.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.